The largest database of trusted experimental protocols

Amicon 10 000 mwco ultra filter

Manufactured by Merck Group
Sourced in United States

The Amicon 10,000 MWCO ultra filter is a laboratory filtration device used for the separation and concentration of macromolecules, such as proteins and nucleic acids, based on their molecular weight. It operates by applying pressure or centrifugal force to push a sample solution through a semi-permeable membrane, allowing smaller molecules to pass through while retaining the larger molecules of interest.

Automatically generated - may contain errors

Lab products found in correlation

4 protocols using amicon 10 000 mwco ultra filter

1

Dialysis Purification of Nano-Formulations

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dialysis tubing technique was used to purify the synthesized nano-formulations GA for eliminating impurities and free non-conjugated compounds suspended in the solution by eluting it through regenerated cellulose (Amicon 10,000 MWCO ultra filter, Millipore, USA). The Entrapment efficiency (EE%) for GA was measured and processed with the microplate reader (BMG Labtech, Germany). The compound entrapment efficiency was calculated from the ratio of the compound amount incorporated into the NPs to total added compound amount.
+ Open protocol
+ Expand
2

Quantifying Encapsulated Drug in Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
The EE% of the VRM NPs and APT-VRM NPs was performed to determine the encapsulated VRM in the nanoparticles. The prepared NPs were introduced to a dialysis tube (Amicon 10,000 MWCO ultrafilter, Millipore, USA) for eliminating the impurities and the free non-entrapped VRM.
+ Open protocol
+ Expand
3

Gallic Acid Calibration Curve and Nanocomposite Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Calibration curve was generated for gallic acid using serial dilutions of each compound (0, 10, 20, 50, 100 µM). All data were equipped and processed with the microplate reader (BMG Labtech, Germany). The compound entrapment efficiency (EE) was calculated from the ratio of the compound amount incorporated into the nanocomposite to the total added compound amount. The prepared nano-structures were enrolled to dialysis tubing technique for eliminating the impurities and the free non-conjugated compounds suspended in the solution by eluting it through regenerated cellulose (Amicon 10,000 MWCO ultra filter, Millipore, USA).
+ Open protocol
+ Expand
4

Dialysis Tubing Purification of NPs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dialysis tubing technique was used to purify the synthesized NPs for eliminating the impurities and the free non-conjugated compounds suspended in the solution by eluting it through regenerated cellulose (Amicon 10,000 MWCO ultra filter, Millipore, USA). The Entrapment efficiency (EE%) for the NPs were measured and processed with the microplate reader (BMG Labtech, Germany). The compound entrapment efficiency was calculated from the ratio of the compound amount incorporated into the NPs to the total added compound amount [28] .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!