The largest database of trusted experimental protocols

Hemoglobin

Manufactured by Tecan
Sourced in Switzerland

Hemoglobin is a protein found in red blood cells that is responsible for transporting oxygen throughout the body. It is a key component in the analysis and measurement of various blood parameters in a laboratory setting.

Automatically generated - may contain errors

2 protocols using hemoglobin

1

Quantifying Alveolar Hemorrhage from BALF

Check if the same lab product or an alternative is used in the 5 most similar protocols
BALF total protein was measured with a Pierce BCA Protein Assay Kit (Thermo Scientific). Alveolar hemorrhage was assessed as described elsewhere (32 (link)), but with the following modifications. A 6X 2-fold serial dilution (8000–250 μg/mL) of human hemoglobin (Sigma, St. Louis, MO) was prepared, and 50 μL of each standard and BALF sample were added to duplicate wells of a 96-well plate. A volume of 100 μL of 6% sodium dodecyl sulfate (Sigma, St. Louis, MO) was added to all wells and resuspended several times. The absorbance at 560 nm was measured with a Tecan Infinite M Nano plate reader (Tecan, Männedorf, Switzerland), and alveolar hemorrhage (i.e., total amount of hemoglobin recovered in BALF) was determined from the standard curve generated by Magellan V 7.2 (Tecan, Männedorf, Switzerland) software.
+ Open protocol
+ Expand
2

Quantifying Alveolar Hemorrhage and Cytokines

Check if the same lab product or an alternative is used in the 5 most similar protocols
BALF total protein was measured with a Pierce BCA Protein Assay Kit (Thermo Scientific).
Alveolar hemorrhage was assessed as described elsewhere (30) , but with the following modifications. A 6X 2-fold serial dilution (8000-250 µg/mL) of human hemoglobin (Sigma, St. Louis, MO) was prepared, and 50 µL of each standard and BAL sample was added to duplicate wells of a 96-well plate. A volume of 100 µL of 6% sodium dodecyl sulfate (Sigma) was added to all wells and resuspended several times. The absorbance at 560 nm was measured with a Tecan Infinite M Nano plate reader (Tecan, Männedorf, Switzerland), and alveolar hemorrhage (i.e., total amount of hemoglobin recovered in BAL) was determined from the standard curve generated by Magellan V 7.2 (Tecan) software. (CCL-7), MIP-1α (CCL-3), MIP-1β (CCL-4), MIP-2 (CXCL-2), RANTES (CCL-5), Eotaxin (CCL-11), GM-CSF, IFN gamma, and TNF alpha (31) . All samples from bead-based assays were performed using a LiquiChip-200 instrument (Qiagen, Hilden, Germany) using Bio-Plex Manager v6.1 software for quantification.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!