T3 hss nano column

Manufactured by Waters Corporation

The T3 HSS nano-column is a high-performance liquid chromatography (HPLC) column designed for nano-scale separation applications. It features a packed bed of small-diameter particles that enable efficient separation and high-resolution analysis of complex samples. The core function of the T3 HSS nano-column is to provide a robust and reliable platform for the separation and purification of various biomolecules and other analytes at the nano-scale level.

Automatically generated - may contain errors

20 protocols using t3 hss nano column

1

Nano-UPLC-MS Peptide Separation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split-less nano-Ultra Performance Liquid Chromatography (10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was: A) H2O + 0.1% formic acid and B) acetonitrile +0.1% formic acid. Desalting of the samples was performed online using a reversed-phase C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; Waters) at 0.35 μL/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 30% B in A (vol/vol) in 105 min, 35% to 90% B in A in 5 min, maintained at 95% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
2

Nanoscale Protein Separation and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Dry digested samples were dissolved in 97:3% H2O/acetonitrile + 0.1% formic acid. Each sample was loaded using split-less nano-Ultra Performance Liquid Chromatography (10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was (A) H2O + 0.1% formic acid and (B) acetonitrile + 0.1% formic acid. Desalting of the samples was performed online using a reversed-phase Symmetry C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; Waters) at 0.35 μL/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4 to 30%B in 55 min, 30 to 90%B in 5 min, maintained at 90% for 5 min, and then back to initial conditions.
+ Open protocol
+ Expand
3

Nano-UPLC Peptide Separation and MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split-less nano-Ultra Performance Liquid Chromatography (10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was: (A) H2O + 0.1% formic acid and (B) acetonitrile +0.1% formic acid. Desalting of the samples was performed online using a reversed-phase C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; Waters) at 0.35 μL/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 22%B in 145 min, 22% to 90%B in 20 min, maintained at 95% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
4

Nano-UPLC-MS-Based Proteomics Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split-less nanoUltra Performance Liquid Chromatography (10 kpsi nano-Acquity; Waters, Milford, MA, USA). The mobile phase was: A) H2O + 0.1% formic acid and B) acetonitrile + 0.1% formic acid. Dry peptides were dissolved in 97:3 water:acetonitrile (v/v) + 0.1% formic acid solution. Desalting of the samples was performed online using a reversed-phase C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; Waters) at 0.35 μL/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 20%B in 140 min, 20% to 90%B in 25 min, maintained at 90% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
5

Nano-UPLC-MS/MS Proteomics Workflow

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS‐grade solvents were used for all chromatographic steps. Each sample was loaded using split‐less nano‐Ultra Performance Liquid Chromatography (10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was: (A) H2O + 0.1% formic acid, and (B) acetonitrile +0.1% formic acid. Desalting of the samples was performed online using a reversed‐phase Symmetry C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; Waters). The peptides were then separated using a T3 HSS nano‐column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; Waters) at 0.35 μl/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4–30% B over 55 min, 30–90% B over 5 min, maintained at 90% for 5 min and then back to the initial conditions. The nanoUPLC was coupled online through a nanoESI emitter (10 μm tip; New Objective, Woburn, MA, USA) to a quadrupole orbitrap mass spectrometer (Q Exactive HF; Thermo Scientific) using a FlexIon nanospray apparatus (Proxeon). Data were acquired in data‐dependent acquisition (DDA) mode, using a Top10 method. MS1 resolution was set to 120,000 (at 200 m/z), mass range of 375–1,650 m/z and AGC of 3e6, and maximum injection time was set to 60 ms. MS2 resolution was set to 15,000, quadrupole isolation 1.7 m/z, AGC of 1e5, dynamic exclusion of 20 s and maximum injection time of 60 ms.
+ Open protocol
+ Expand
6

Nanoscale LC-MS Peptide Separation

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split-less nano-ultra performance liquid chromatography (10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was: A) H2O + 0.1% formic acid and B) acetonitrile + 0.1% formic acid. Desalting of the samples was performed online using a reversed-phase Symmetry C18 trapping column (180 µm internal diameter, 20 mm length, 5 µm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 µm internal diameter, 250 mm length, 1.8 µm particle size; Waters) at 0.35 µL/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 27%B in 105 min, 27% to 90%B in 5 min, maintained at 90% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
7

High-resolution Nanoscale Proteomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split‐less nano‐ultra performance liquid chromatography (10 kpsi MClass; Waters, Milford, MA, USA). The mobile phase was: a) H2O + 0.1% formic acid and b) acetonitrile + 0.1% formic acid. Desalting of the samples was performed online using a reversed‐phase Symmetry C18 trapping column (180 µm internal diameter, 20 mm length, 5 µm particle size; Waters). The peptides were then separated using a T3 HSS nanocolumn (75 µm internal diameter, 250 mm length, 1.8 µm particle size; Waters) at 0.35 µL min−1. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 30%B in 155 min, 30% to 90%B in 5 min, maintained at 90% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
8

Nano-UPLC-MS Peptide Separation and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Each sample was loaded using split-less nano-Ultra Performance Liquid Chromatography (10 kpsi nanoAcquity; Waters, Milford, MA). The mobile phase was: A: H2O + 0.1% formic acid and B: acetonitrile + 0.1% formic acid. Desalting of the samples was performed online using a reversed-phase C18 trapping column (180 μm internal diameter, 20 mm length, 5 μm particle size; waters). The peptides were then separated using a T3 HSS nano-column (75 μm internal diameter, 250 mm length, 1.8 μm particle size; waters) at 0.35 μl/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4% to 20% B in 155 min, 20% to 90% B in 5 min, maintained at 90% B for 5 min and then back to initial conditions.
+ Open protocol
+ Expand
9

Quantitative Proteomic Analysis of Cellular Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Sorted cell pellets were lysed in 50 mM Tris-HCl pH 7.4, 5% SDS, and sonicated (Bioruptor Pico, Diagenode, USA). Protein concentration was measured using the BCA assay (Thermo Scientific, USA). From each sample, 20 μg of total protein was subjected to in-solution tryptic digestion using the suspension trapping (S-trap) method as previously described [49 (link)]. Liquid chromatography and Mass Spectrometry was performed as described previously [24 (link)], using split-less nano-Ultra Performance Liquid Chromatography, reversed-phase Symmetry C18 trapping column (Waters) and a T3 HSS nano-column (Waters) for desalting and separation, coupled to a quadrupole orbitrap mass spectrometer (Q Exactive HFX, Thermo Scientific). Data acquisition, processing and analysis was performed as described [20 (link)]. Differential protein abundance was tested using the glht R function by ANOVA followed by Tukey analysis on the intensity values using a logarithmic scale. Changes in protein abundance of at least 1.5 between conditions, with p.value < 0.05 were considered significant.
+ Open protocol
+ Expand
10

Nano-UPLC-MS Peptide Separation and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
ULC/MS grade solvents were used for all chromatographic steps. Dry digested samples were dissolved in 97:3% H2O/acetonitrile containing 0.1% formic acid. Each sample was loaded using split-less nano-ultra performance liquid chromatography (nanoUPLC; 10 kpsi nanoAcquity; Waters, Milford, MA, USA). The mobile phase was: (A) H2O with 0.1% formic acid and (B) acetonitrile with 0.1% formic acid. Samples were desalted online using a reversed-phase Symmetry C18 trapping column (180 µm internal diameter, 20 mm length, 5 µm particle size; Waters). The peptides were then separated using a T3 HSS nano-column (75 µm internal diameter, 250 mm length, 1.8 µm particle size; Waters) at 0.35 µl/min. Peptides were eluted from the column into the mass spectrometer using the following gradient: 4–20% B in 155 min, 20–90% B in 5 min, maintained at 90% for 5 min and then back to initial conditions.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!