The largest database of trusted experimental protocols

Chemdraw ultra 10

Manufactured by Revvity Signals Software

ChemDraw Ultra 10.0 is a chemical structure drawing software. It allows users to create, edit, and analyze chemical structures and reactions. The software provides tools for drawing and manipulating 2D and 3D molecular structures, as well as features for generating chemical formulas, spectra, and other related information.

Automatically generated - may contain errors

5 protocols using chemdraw ultra 10

1

Determining Lipophilicity and Polarity

Check if the same lab product or an alternative is used in the 5 most similar protocols
The Clog P and Mlog values were calculated using the ChemDraw Ultra 10.0 [57 ] or MedChem Designer (TM) 3.0.0.30 [58 ], respectively.
+ Open protocol
+ Expand
2

Conformational Analysis and Molecular Docking

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 2D structure of 12 derivatives of bisindole-2-carboxilic acids was sketched in ChemDraw Ultra 10.0, converted to conformation in Chem3D 10.0, and then energy minimized in Discovery Studio 3.5 with a Merck molecular force field (Merck & Co.) until the minimum RMS reached 0.001 in Chem3D Ultra 10.0. The energy optimized conformations in whole conformational space of the derivatives were sampled with systematic search and BEST method of Discovery Studio 3.5, which were practiced with a SMART minimizer using CHARMM force field. The energy threshold was set to 20 kcal/mol at 300 K. The maximum minimization steps were 200 and the minimization root mean squared (RMS) gradient was 0.1 Å. The maximum generated conformations were 255 with a RMS deviation (RMSD) cutoff of 0.2 Å. Top 10 energy optimized conformations of DEBIC were used for the docking to d(CGATCG)2 and P-selectin.
+ Open protocol
+ Expand
3

Conformational Analysis of THPDTPI

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 2D structure of THPDTPI was sketched in ChemDraw Ultra 10.0, converted to 3D conformation in Chem3D 10.0, and then energy minimized in Discovery Studio 3.5 with a Merck molecular force field (Merck & Co.) until the minimum RMS reached 0.001. The energy optimized conformations in the whole conformational space of THPDTPI were sampled with systematic search and BEST method of Discovery Studio 3.5, which were practiced with a SMART minimizer using CHARMM force field. The energy threshold was set to 20 kcal/mol at 300 K. The maximum minimization steps were 200 and the minimization root mean squared (RMS) gradient was 0.1 Å. The maximum generated conformations were 255 with a RMS deviation (RMSD) cutoff of 0.2 Å. Top 10 energy optimized conformations of THPDTPI were used for the docking to the active site of P-selectin.
+ Open protocol
+ Expand
4

Conformational Analysis of IQCA-TAVV

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 2D structure of IQCA-TAVV was sketched in ChemDraw Ultra 10.0, converted to 3D conformation in Chem3D 10.0, and then energy was minimized until the minimum RMS to reach 0.001 in Chem3D Ultra 10.0. The energy optimized conformations in the whole conformational space of IQCA-TAVV were sampled with systematic search and BEST method of Discovery Studio 3.5, which were practiced with a SMART minimizer using CHARMM force field. The energy threshold at 300 K was 20 kcal/mol. The maximum minimization steps were 200 and the minimization root mean squared (RMS) gradient was 0.1 Å. The maximum generated conformations were 255 with a RMS deviation (RMSD) cutoff of 0.2 Å. The lowest energy conformation of IQCA-TAVV was used for the docking to the active site of P-selectin and GPIIb/IIIa.
+ Open protocol
+ Expand
5

Conformational Analysis of PZL318 Compound

Check if the same lab product or an alternative is used in the 5 most similar protocols
The 2D structure of PZL318 was sketched in ChemDraw Ultra 10.0. The 3D structure was created and energy minimized until the minimum RMS reached 0.001 in Chem3D Ultra 10.0. The 3D structure was then energy minimized in Discovery Studio 2.1 with the Merck molecular force field. The energy-minimized conformation was used as the starting point for the conformation generation for PZL318. Energy-minimized conformations were sampled in the whole conformational space via the systematic search method and the BEST method in Discovery Studio 2.1. The systematic search and BEST methods were both performed with the SMART minimizer using the CHARMM force field. The energy threshold was set to 20 kcal/mol at 300 K. The maximum minimization steps were set to 200, and the minimization RMS gradient was set to 0.1 Å. The maximum generated conformations were set to 255 with an RMSD cutoff of 0.2 Å. The association model shown was proposed according to the 3D structure and the intermolecular interactions identified with the rotating-frame Overhauser spectroscopy (ROESY) 2D NMR and ESI-MS spectra of PZL318.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!