The largest database of trusted experimental protocols

D8 venture apex 3

Manufactured by Bruker

The D8 Venture (APEX-III) is a versatile laboratory equipment designed for X-ray diffraction analysis. It features high-performance components and advanced technology for accurate and reliable data collection. The core function of the D8 Venture is to enable researchers and scientists to perform X-ray diffraction studies on a wide range of materials.

Automatically generated - may contain errors

2 protocols using d8 venture apex 3

1

Multimodal Characterization of Novel Materials

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H and 13C NMR
spectra were recorded using a Bruker 500 MHz NMR spectrometer. ESI-MS
mass spectra were recorded on an Advion compact mass spectrometer
(serial no. 3013-0140). Infrared spectra were recorded on a PerkinElmer
FT-IR Spectrum 100 spectrophotometer. UV–vis spectra were recorded
on a CARY 60 spectrophotometer. Solid- and solution-state fluorescence
spectra were recorded in a Varian Cary Eclipse fluorescence spectrophotometer
and a PerkinElmer LS 45 instrument. The X-ray crystallographic data
were taken from Bruker D8 Venture (APEX-III) with a photon detector.
Powder X-ray diffraction (PXRD) analysis was carried out by Bruker
AXS (Germany) with a model no. of D8 FOCUS. FE-SEM analysis was carried
out using Sigma HD, Zeiss, Oxford Instruments, Germany. The change
of particle size before and after the interaction with water and Cu2+ was monitored by DLS studies (Zetasizer Nano ZS90). Cyclic
voltammetry was performed in a CH instrument.
+ Open protocol
+ Expand
2

Synthesis and Characterization of DNMH

Check if the same lab product or an alternative is used in the 5 most similar protocols
The required synthons and solvents are commercially available and were used as obtained. All the TBA+X salts including cyanide, fluoride, chloride, acetate, bromide, nitrates, and carbonates were procured from Sigma Aldrich and iodide and sulphates were purchased from Alfa Aesar. Spectroscopic-grade solvents like acetonitrile, dimethyl sulfoxide and water have been obtained from Merck (India) Pvt. Ltd.
DNMH has been structurally confirmed by mass spectrometry (Advion Make; Serial no. 3013-0140) and 1H-NMR spectroscopy (Bruker 400 MHz NMR spectrometer). The functional groups within the DNMH scaffold have been authenticated by FT-IR spectroscopy (Spectrum 65, PerkinElmer). X-ray crystallography was performed in a Bruker D8 Venture (APEX-III) diffractometer equipped with a photon detector and assisted by graphite-monochromated Mo Kα (λ = 0.71073 Å) irradiation. A CARY60 spectrophotometer was used to perform the UV-vis spectrophotometric study. Particle size analysis of DNMH and the DNMH + CN adduct was executed by a dynamic light scattering study (Zetasizer Nano ZS90). Cyclic voltammetry was performed in a CH instrument.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!