The largest database of trusted experimental protocols

Lipid panel plus diskettes

Manufactured by Abaxis
Sourced in United States

The Lipid Panel Plus diskettes are a diagnostic laboratory equipment product from Abaxis. They are designed to perform quantitative analysis of lipid profile parameters in patient samples.

Automatically generated - may contain errors

3 protocols using lipid panel plus diskettes

1

Plasma and Hepatic Lipid Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels for alanine aminotransferase (ALT) and aspartate aminotransferase (AST) and circulating levels of high-density lipoprotein (HDL), triglycerides, and cholesterol were obtained using an Abaxis Piccolo Xpress analyzer (Abbott; Abbott Park, IL, USA) with Lipid Panel Plus diskettes (catalog:400-0030; Abaxis Inc.; Union City, CA, USA). Circulating levels of plasma adipokines and cytokines were measured using a MILLIPLEX® Mouse Adipokine Magnetic Bead Panel (Millipore Sigma, Burlington, MA, USA) for analytes interleukin 6 (IL-6), leptin, total plasminogen activator inhibitor 1 (PAI-1), tumor necrosis factor alpha (TNFα), and resistin. Data was obtained from a Luminex 100/200 System equipped with xPONENT Software (Luminex Corporate, Austin, TX, USA). Hepatic lipids were extracted using a modified Bligh and Dyer method with a 2:1 ratio of chloroform to methanol mixture (27 (link), 28 (link)). Extracted lipids were measured using Infinity Assay Reagents: Infinity Triglycerides reagent (TR22421, ThermoFisher Scientific, Middletown, VA, USA) and Infinity Cholesterol reagent (TR13421, ThermoFisher Scientific, Middletown, VA, USA). Sample absorbance at 500 nm was calculated from a standard curve constructed from clinical standards (catalog: T7531-STD, C7509-STD; Point Scientific; Canton, MI) for each analyte ran simultaneously with unknown samples.
+ Open protocol
+ Expand
2

Plasma and Hepatic Lipid Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels for alanine aminotransferase (ALT) and aspartate aminotransferase (AST) and circulating levels of high-density lipoprotein (HDL), triglycerides, and cholesterol were obtained using an Abaxis Piccolo Xpress analyzer (Abbott; Abbott Park, IL, USA) with Lipid Panel Plus diskettes (catalog:400-0030; Abaxis Inc.; Union City, CA, USA). Circulating levels of plasma adipokines and cytokines were measured using a MILLIPLEX® Mouse Adipokine Magnetic Bead Panel (Millipore Sigma, Burlington, MA, USA) for analytes interleukin 6 (IL-6), leptin, total plasminogen activator inhibitor 1 (PAI-1), tumor necrosis factor alpha (TNFα), and resistin. Data was obtained from a Luminex 100/200 System equipped with xPONENT Software (Luminex Corporate, Austin, TX, USA). Hepatic lipids were extracted using a modified Bligh and Dyer method with a 2:1 ratio of chloroform to methanol mixture (27 (link), 28 (link)). Extracted lipids were measured using Infinity Assay Reagents: Infinity Triglycerides reagent (TR22421, ThermoFisher Scientific, Middletown, VA, USA) and Infinity Cholesterol reagent (TR13421, ThermoFisher Scientific, Middletown, VA, USA). Sample absorbance at 500 nm was calculated from a standard curve constructed from clinical standards (catalog: T7531-STD, C7509-STD; Point Scientific; Canton, MI) for each analyte ran simultaneously with unknown samples.
+ Open protocol
+ Expand
3

Comprehensive Metabolic Profiling Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Liver enzymes, triglycerides, glucose, cholesterol, and lipoproteins (HDL, LDL, VLDL) were measured with Lipid Panel Plus diskettes (catalog:400-0030; Abaxis Inc.; Union City, CA) on the Piccolo Xpress Chemistry Analyzer (Abbott; Abbott Park, IL). Plasma adipokines were measured with the Milliplex Map Mouse Adipokine Magnetic Bead Panels (catalog: MADKMAG-71K; EMD Millipore) on a Luminex® 100 system (Luminex Corp.; Austin, TX). Adipokines measured included Insulin, PAI-1, Resistin, and Leptin. Analysis for each assessment was performed according to the manufacturer’s protocol. Plasma albumin levels were measured via ELISA from MyBioSource Inc. and performed according to the manufacturer’s standard protocol (catalog: MBS564063; San Diego, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!