Gc msd 6890n 5975

Manufactured by Agilent Technologies

The GC/MSD 6890N/5975 is a gas chromatography-mass spectrometry (GC/MS) system manufactured by Agilent Technologies. It is designed to separate and analyze complex mixtures of chemical compounds. The GC component is used to separate the individual components of the mixture, while the MSD (mass selective detector) component is used to identify and quantify those components based on their unique mass-to-charge ratios.

Automatically generated - may contain errors

2 protocols using gc msd 6890n 5975

1

GC-MS Analysis of Compound Identification

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis was performed using an Agilent GC–MSD system (GC/MSD 6890N/5975) equipped with a HP-88 Agilent capillary column (60 m × 0.25 mm; 0.20 μm film thickness), MSD ChemStation ver. E.02.02.1431 software (Agilent Technologies, Santa Clara, CA, USA), and a split–splitless injector. The oven temperature was programmed from 110 °C to 190 °C with 8 °C/min, held for 2 min at 110 °C and 13 min at 190 °C. The temperature of the injector was 250 °C. The injection volume was 1 μL (split ratio 150:1; split flow 180 mL/min). Helium was used as a carrier gas at a flow rate of 1.2 mL/min. A quadrupole mass spectrometer with electron ionization (EI) at 70 eV and with a full scan type acquisition mode (50 m/z to 500 m/z) was used as a detector connected with the GC. The temperature of the MS source and the MS quadrupole was set at 230 °C and 150 °C, respectively. Identification of the constituents was based on a comparison of their mass spectra with the mass spectra library NIST resources and retention times with standards.
+ Open protocol
+ Expand
2

GC-MSD Analysis of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analysis was performed using an Agilent GC-MSD system (GC/MSD 6890N/5975) equipped with a HP-88 Agilent capillary column (60 m × 0.25 mm; 0.20 μm film thickness), MSD ChemStation ver. E.02.02.1431 software (Agilent Technologies, Santa Clara, CA, United States), and a split–splitless injector. The oven temperature was programmed from 110 °C to 190 °C with 8 °C/min, hold for 2 min at 110 °C and 13 min at 190 °C. The temperature of the injector was 250 °C. The injection volume was 1 μL (split ratio 150:1; split flow 180 mL/min). Helium was used as a carrier gas at a flow rate of 1.2 mL/min. A quadrupole mass spectrometer with electron ionization (EI) at 70 eV and with a full scan type acquisition mode (50 m/z to 500 m/z) was used as a detector connected with the GC. The temperature of the MS source and the MS quadrupole was set to 230 °C and 150 °C, respectively. The identification of the constituents was based on a comparison of their mass spectra with the mass spectra library NIST resources and retention times with standards. Each sample was measured in three replicates.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!