The largest database of trusted experimental protocols

Us avance 3 7.0t system

Manufactured by Bruker
Sourced in Germany

The 70/16 US AVANCE III 7.0T system is a high-field nuclear magnetic resonance (NMR) spectrometer designed for advanced research and applications. It features a 7.0 Tesla superconducting magnet and the AVANCE III electronics platform. The system is capable of performing a wide range of NMR experiments and analyses, providing researchers with a powerful tool for structural elucidation, metabolic profiling, and various other applications in the fields of chemistry, biology, and materials science.

Automatically generated - may contain errors

Lab products found in correlation

3 protocols using us avance 3 7.0t system

1

High-Resolution 7T MRI Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MR data were collected on a Bruker 70/16 US AVANCE III 7.0T system (380 mT/m gradient strength on each (X, Y, and Z) axis, slew rate of 3420 T/m/s) using a Bruker surface coil. A gradient-recalled echo localizer scan was used to position the animals in the scanner and for graphical prescription of the subsequent scans. T2-weighted, high-resolution, TurboRare acquisition sequence: TR = 6000 ms; TE = 33 ms; 0.2 mm isotropic voxels, Matrix = 160 × 160; 2 averages; echo train length = 8; slice thickness = 0.5 mm; interslice gap = 0.5 mm; 32 slices.
+ Open protocol
+ Expand
2

High-Resolution MRI Acquisition Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
MR data were collected on a Bruker 70/16 US AVANCE III 7.0T system (Karlsruhe, Germany) with 380mT/m gradient strength on each (X, Y, and Z) axis, slew rate of 3420 T/m/s, 16cm bore size using a Bruker surface coil and ParaVision 6.1 software. A gradient-recalled echo (GRE) localizer scan was used to position the animals in the scanner and for graphical prescription of the subsequent scans. T2-weighted, high-resolution, TurboRare acquisition sequence: repetition time (TR) = 6774.8ms; echo time (TE) = 33ms; 0.2mm isotropic voxels, matrix = 160 × 160; 2 averages; slice thickness= 0.5mm. Differences between acquisitions were as follows: experiment 1 collected 64 slices; experiment 2 collected 32 slices.
+ Open protocol
+ Expand
3

High-Resolution 7T MRI Structural Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
MR data were collected on a Bruker 70/16 US AVANCE III 7.0T system (Karlsruhe, Germany) with 380 mT/m gradient strength on each (X, Y, and Z) axis, slew rate of 3420 T/m/s, 16 cm bore size using a Bruker surface coil and ParaVision 6.1 software. A gradient-recalled echo (GRE) localizer scan was used to position the animals in the scanner and for graphical prescription of subsequent scans. The T2-weighted, high-resolution, TurboRare acquisition for structural analysis had the following parameters: repetition time (TR) = 6000 ms; echo time (TE) = 33 ms; 0.2 mm isotropic voxels; matrix = 160 × 160; 2 averages; echo train length = 8; slice thickness = 0.5 mm; 32 slices.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!