The Bioplex multiplex cytokine assay system is a laboratory equipment designed to measure multiple cytokines and chemokines simultaneously in a single sample. It utilizes fluorescent-labeled beads coated with specific antibodies to capture and detect target analytes. The system enables efficient and accurate quantification of various immune-related proteins, providing researchers with a comprehensive analysis of complex biological samples.

Automatically generated - may contain errors

8 protocols using bioplex multiplex cytokine assay system

1

Quantification of Inflammatory Mediators

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of LXA4, 15-epi-LXA4, PGE2, and LTB4 were measured using the MyBioSource.com quantitative measurement kit and plasma levels of IL-1α, IL-1β, IFNγ, and TNFα were measured using Bio-Plex multiplex cytokine assay system (Bio-Rad, Hercules, CA). The lowest detection limits were as follows LXA4, 0.156 ng/mL; 15-epi-LXA4, 0.312 ng/mL; PGE2, 7.8 pg/mL; LTB4, 15.6 pg/mL; IL-1α, 5.23 pg/mL; IL-1β, 3.96 pg/mL; IFNγ, 4.39 pg/mL, and TNFα, 3.24 pg/mL.
+ Open protocol
+ Expand
2

Multiplex Cytokine and Chemokine Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Circulating levels of cytokines and chemokines were measured using Bio-Plex multiplex assay system (Bio-Rad, Hercules, CA). Circulating levels of IFNγ, IL-2, TNFα, IL-17A, IL-22, IL-1β, IL-6, IL-12, GM-CSF, IL-4, IL-5, IL-13 and IL-10 were measured using the Bio-Plex multiplex cytokine assay system (Bio-Rad, Hercules, CA). TGFβ alone was measured using the R & D Systems Quantikine ELISA. The lowest detection limits were as follows: IFNγ, 4.39 pg/mL; IL-2, 29.63 pg/mL; TNFα, 3.24 pg/mL; IL-17A, 1.69 pg/mL; IL-22, 12.63 pg/mL; IL-1β, 3.96; IL-6, 7.7 pg/mL; IL-12, 4.66 pg/mL; GM-CSF, 12.22 pg/mL; IL-4, 14.61 pg/mL; IL-5, 6.63 pg/mL; IL-13, 216.2 pg/mL; IL-10, 4.65 pg/mL and TGFβ, 7.8 pg/mL. Luminex Human Chemokines Magnetic Assay kit (R & D systems) was used to measure the chemokine levels of CCL1, CCL2, CCL3, CCL4, CCL-11, CXCL1, CXCL2, CXCL9, CXCL10, and CXCL11. The lowest detection limits were as follows: CCL1, 1.57 pg/mL; CCL2, 31.8 pg/mL; CCL3, 90.9 pg/mL; CCL-4, 133.1 pg/mL, CCL11, 21.6 pg/mL; CXCL1, 49.2 pg/mL; CXCL2, 49.2 pg/mL; CXCL9, 600.6 pg/mL CXCL10, 2.88 pg/mL and CXCL11, 21.6 pg/mL.
+ Open protocol
+ Expand
3

Multiplex Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Circulating plasma cytokine levels were measured using a bio-plex multiplex cytokine assay system (Bio-Rad, Hercules, CA). The analytes measured were IFN-γ, TNF-α, IL-2, IL-4, IL-5, IL-13, IL-12, IL-17A, IL-22, IL-10, IL-1α, IL-1β, IL-6 and GM-CSF. The experiment was carried out according to the manufacturer’s instruction provided (R & D systems). The standard ranges of each cytokine were as follows: IFN-γ-49.18–11,950 pg/ml, TNF-α-8.89–2,160 pg/ml, IL-2-31.11–7,560 pg/ml, IL-4-15.72–3,820 pg/ml, IL-5-6.5–1,580 pg/ml, IL-13-367.78–89,370 pg/ml, IL-12-133.58–32,460 pg/ml, IL-17A-12.47–3,030 pg/ml, IL-22-14.28–3,470 pg/ml, IL-10-3.62–880 pg/ml, IL-1α-5.31–1,290 pg/ml, IL-1β-16.3–3,960 pg/ml, IL-6-4.53–1,100 pg/ml and GM-CSF-11.58–2,900 pg/ml.
+ Open protocol
+ Expand
4

Multiplex Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma cytokines on all 50 individuals were measured using Bioplex multiplex cytokine assay system (Biorad). The cytokines analyzed were IL-2, IFN-γ, TNF-α, IL-10, IL-17A, IL-17F and IL-22. TGFβ levels were measured using a standard ELISA kit from R&D Systems.
+ Open protocol
+ Expand
5

Plasma Cytokine Profiling Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma cytokines were measured using a Bioplex multiplex cytokine assay system (Bio-Rad, Hercules, CA). The parameters analyzed were IFNγ, TNFα, IL-2, IL-17A, IL-4, IL-5, IL-10, IL-6, IL-12p70 and GM-CSF. Plasma levels of TGFβ, IL-1α, IL-1β (all R& D Systems); IL-17F (Biolegend); IL-22 (eBioscience); Type 1 interferons (IFNs) - IFNα (multiple subtypes) and IFNβ (PBL Interferon Source) were measured by ELISA. All samples were run in duplicates.
+ Open protocol
+ Expand
6

Multiplex Adipocytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma was collected in Heparin Sodium tubes and after centrifugation stored at −80°C. Bioplex multiplex cytokine assay system (Bio-Rad, Hercules, CA) were used to measures the adipocytokines levels. The parameters analyzed were adiponectin, adipsin, leptin, resistin, visfatin and PAI-1. All assays were run in duplicates. The lower limit of detection were: adiponectin, 3654 pg/ml; adipsin, 1496 pg/ml; leptin, 1476 pg/ml; resistin, 197 pg/ml; visfatin, 10628 pg/ml and PAI-1, 552 pg/ml.
+ Open protocol
+ Expand
7

Multiplex Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma cytokines were measured using a Bioplex multiplex cytokine assay system (Bio-Rad). The parameters analyzed were IFNγ, TNFα, IL-2, IL-17A, IL-4, IL-5, IL-13, IL-10, IL-6, IL-12 and GM-CSF. Plasma levels of TGFβ, IL-1α, IL-1β, IL-18, IL-22 (all R& D Systems) and IL-17F (Biolegend) were measured by ELISA.
+ Open protocol
+ Expand
8

Plasma Cytokine and Chemokine Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma cytokines and chemokines were measured using a Bioplex multiplex cytokine assay system (Bio-Rad, Hercules, CA). The parameters analyzed were IFNγ, TNFα, IL-2, IL-17A, IL-4, IL-5, IL-10, IL-6, IL-12 and GM-CSF. Plasma levels of TGFβ, IL-1α, IL-1β (all R& D Systems); IL-17F (Biolegend); IL-22 (eBioscience); Type 1 interferons (IFNs) - IFNα (multiple subtypes) and IFNβ (PBL Interferon Source) were measured by ELISA.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!