The largest database of trusted experimental protocols

Dmi 140 sc

Manufactured by Mettler Toledo
Sourced in Switzerland

The DMI 140-SC is a density meter designed for the precise measurement of the density and concentration of liquids. It utilizes the oscillating U-tube principle to determine the density of the sample. The instrument is capable of measuring a wide range of densities and provides reliable and accurate results.

Automatically generated - may contain errors

2 protocols using dmi 140 sc

1

Determination of Zinc Pyrithione in Shampoo

Check if the same lab product or an alternative is used in the 5 most similar protocols
ZnPT determination in shampoo was performed using complexometric and potentiometric titrations. For the complexometric titration, 6.0 g of the sample were weighed and diluted in water (50 mL). Then, 2.5 mL of hydrochloric acid were added while heating and gently stirring for ten min. 0.5 mL of hydrogen peroxide was added, and the mixture was cooled simultaneously. pH was adjusted with an ammonia solution and 2.5 mL of buffer solution (pH = 10). Finally, the sample was titrated with EDTA (0.01 M) using eriochrome black T as an indicator. The equivalence point occurred when the color of the solution changes from violet to blue.
For the potentiometric titration, 6.3 g of the sample was weighed and transferred to the cell of the automatic titrator (Mettler Toledo, T70) along with 50 mL of water and 10 mL of fuming hydrochloric acid. The resulting sample was titrated with an iodine solution (0.05 M) where the final point of the titration was indicated by a platinum electrode (Mettler Toledo, DMI 140-SC). Constant stirring was ensured during the titration.
+ Open protocol
+ Expand
2

Detailed Analytical Techniques for Oil Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
Abbe refractometer ORT1RS and Mettler Toledo G20 Compact Titrator equipped with a combined platinum electrode (Mettler Toledo DMI140-SC, Schwerzenbach, Switzerland) were used to measure refractive index and peroxide value, respectively. Molecular UV absorptivities values were measured using an Agilent 8453 spectrophotometer. An oil monitor electrochemical probe FOM320 Ebro device was employed to quickly measure total polar compound (%TPC). Technical data provided by the device supplier ensure good correlation with the recognised chromatographic method for the most common oils running in the ‘semiliquid’ equipment mode [16 ], and its performance was periodically checked with a suitable reference oil (Testo 05542650). An Agilent 7820A gas chromatographer equipped with an autosampler (7693) and a mass spectrometer (5977B MSD), using Rtx-65TG (30 m × 0.25 mm i.d., 0.1 μm) capillary column was applied for chromatographic analyses.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!