The largest database of trusted experimental protocols

Millipore chemokine and cytokine assay

Manufactured by Merck Group

The Millipore Chemokine and Cytokine Assay is a multiplex detection system designed for the quantitative measurement of multiple analytes in a single sample. The assay utilizes bead-based technology and is compatible with a variety of sample types, including cell culture supernatants, serum, and plasma.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using millipore chemokine and cytokine assay

1

Multiplexed Plasma Biomarker Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Peripheral blood was collected and plasma was isolated and stored at − 80 °C until assays were performed. Plasma was defrosted and centrifuged minutes before the assay. All samples were analyzed for IL-1α (Millipore Chemokine and Cytokine Assay, Millipore), MMP-3, and -7 were investigated with magnetic bead Luminex assays (R&D Systems). S100A9 (R&D Systems), MMP11, MMP25, MMP28 (mybiosource.com), and CTSK (Novus Biologicals) were measured by ELISA. Each sample was run in triplicate. The coefficient of variation (CV) was performed for triplicate wells and CV > 20% were removed.
+ Open protocol
+ Expand
2

Multiplex Cytokine and Protease Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
All samples were analyzed for epidermal growth factor (EGF), interferon (IFN)-α2, IFNγ, interleukin-1 receptor antagonist (IL-1RA), interleukin (IL)-1α, IL-1β, IL-2, IL-3, IL-4, IL-5, IL-6, IL-7, IL-10, IL-12p40, IL-12p70, IL-15, IL-13, IL-17A, IL-8, granulocyte-macrophage colony-stimulating factor (GM-CSF), granulocyte colony-stimulating factor (G-CSF), monocyte chemoattractant protein-1 (MCP-1), macrophage inflammatory protein (MIP)-1α, MIP-1β, interferon gamma-induced protein (IP)-10, tumor necrosis factor (TNF)-α, TNF-β, eotaxin, and vascular endothelial growth factor (VEGF) using a human cytokine 29-multiplex panel (Millipore Chemokine and Cytokine Assay, Millipore). The detection threshold ranged from 0.4 to 26.3 pg/mL over all the 29 bead assay targets. Cathepsin S (CTSS) and matrix metallopeptidase 12 (MMP-12) levels were quantified using a human multiplex bead assay (R&D Systems).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.