The largest database of trusted experimental protocols

Milliplex magnetic bead panel kits

Manufactured by Thermo Fisher Scientific
Sourced in France

Milliplex magnetic bead panel kits are a multiplex assay system designed for the simultaneous quantification of multiple analytes in a single sample. The kits utilize color-coded magnetic beads coated with capture antibodies specific to the target analytes. The assay protocol involves incubating the sample with the magnetic beads, followed by detection antibodies and reporter molecules. The analytes are then measured using a flow cytometry-based instrument.

Automatically generated - may contain errors

2 protocols using milliplex magnetic bead panel kits

1

Multiplex Cytokine Profiling in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma levels of pro-inflammatory cytokines (interleukin 1β (IL-1β) and Tumor Necrosis Factor α (TNFα)), anti-inflammatory cytokines (interleukin 4 (IL-4) and interleukin 10 (IL-10)), monocyte/macrophage chemokines (Macrophage Inflammatory Protein (MIP-1α), Monocyte Chemoattractant Protein (MCP-1)) and osteoprotegerin (OPG) were measured by using Milliplex magnetic bead panel kits (eBioscience, Vienne, Austria) that were analyzed using a Luminex MAGPIX system (Luminex Corporation; Houston, TX) and Milliplex Analyst software (Millipore; St. Charles, MO). The limits of detection provided by the manufacturer for IL-1β, TNFα, IL-4, IL-10, MIP-1α, MCP-1 and OPG were (pg/mL) 13, 3.78, 0.82, 8.59, 2.32, 18 and 1 respectively.
+ Open protocol
+ Expand
2

Cytokine Levels in Inflammatory Models

Check if the same lab product or an alternative is used in the 5 most similar protocols
Levels of TNF-α, IL-17A and IL-1β levels were measured using Milliplex magnetic bead panel kits (eBioscience, Vienna, Austria) that were analyzed using a Luminex MAGPIX system (Luminex Corporation; Houston, TX) and Milliplex Analyst software (Millipore; St. Charles, MO). The limits of detection provided by the manufacturer for IL-17A, IL-1β and TNFα were 3.32 pg/mL, 13 pg/mL and 3.78 pg/mL respectively. IL-6 levels were measured using ELISA technique (rat IL6 platinum ELISA, BMS625®, eBioscience, Vienna, Austria—detection limit: 12 pg/ml).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!