Liaison direct renin kit

Manufactured by DiaSorin
Sourced in Italy

The LIAISON Direct Renin kit is a laboratory equipment product manufactured by DiaSorin. It is used for the quantitative determination of renin in human serum and plasma samples. The kit utilizes a chemiluminescent immunoassay technology to measure renin levels.

Automatically generated - may contain errors

6 protocols using liaison direct renin kit

1

Plasma Renin and Aldosterone Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma renin concentration (PRC) and plasma aldosterone concentration were measured by chemiluminescence immunoassay using the LIAISON Direct Renin kit (DiaSorin S.p.A, Vercelli, Italy) and the LIAISON Aldosterone kit (DiaSorin Inc., Stillwater, MN, USA). Plasma was collected from patients after 2 hours of upright position for measuring PRC and plasma aldosterone concentration.
+ Open protocol
+ Expand
2

Plasma Renin and Aldosterone Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
The plasma renin concentration and plasma aldosterone concentration (PAC) were measured by chemiluminescence immunoassay using the LIAISON® direct renin kit (DiaSorin S.p.A, Vercelli, Italy) and the LIAISON® aldosterone kit (DiaSorin Inc., Stillwater, MN, USA). Other biochemical examinations were performed using standard protocols.
+ Open protocol
+ Expand
3

Aldosterone and Renin Measurement

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were centrifuged and tested immediately after collection. PRA and PACRIA were measured by RIA with the RENCTK RIA kit (DiaSorin, Saluggia, Italy) and ALDOCTK-2 (DiaSorin, Saluggia, Italy) according to the manufacturer's instructions. DRC and PACCLIA were detected by CLIA using the LIAISON® Direct Renin kit (DiaSorin, Saluggia, Italy) and the LIAISON® XL Aldosterone kit on the corresponding fully automated analyzer (DiaSorin, Saluggia, Italy) according to the manufacturer's protocol. The equations of ARR and ADRR are as follows: ARR= PRA/PACRIA; ADRR=DRC/  PACCLIA.
+ Open protocol
+ Expand
4

Comprehensive Diagnostic Evaluation for Adrenal Disorders

Check if the same lab product or an alternative is used in the 5 most similar protocols
Imaging examinations were performed during the proband’s hospitalization, including echocardiography, abdomen ultrasound and CT of the kidneys, adrenal glands and renal arteries. Biochemical evaluations performed included urine protein, microalbuminuria, adrenocorticotropin and serum cortisol on different occasions. Plasma renin concentration (PRC) and PAC were measured for all the participants at Fuwai Hospital by a chemiluminescence immunoassay using the LIAISON Direct Renin kit (DiaSorin S.p.A, Vercelli, Italy) and the LIAISON Aldosterone kit (DiaSorin Inc., Stillwater, USA). The other biochemical examinations were measured using standard methods.
+ Open protocol
+ Expand
5

Adrenal and Renal Imaging Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Computed tomography of the kidneys, adrenal glands, and renal arteries and echocardiography were performed on the proband. PRC and PAC were measured in 8 subjects (Table 1) after they had remained in an upright position for 2 h. PRC and PAC were measured by chemiluminescence immunoassay using a LIAISON Direct Renin kit (DiaSorin S.p.A, Vercelli, Italy) and a LIAISON Aldosterone kit (DiaSorin Inc., Stillwater, MN, USA), respectively. Other biochemical measurements were made using standard methods.
+ Open protocol
+ Expand
6

Comprehensive Hypertension Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
Imaging examinations were performed including echocardiography, abdomen ultrasound, and computed tomography (CT) of the kidneys, adrenal glands, and renal arteries. Laboratory testing covered general biochemical measurements associated with hypertension, such as serum electrolytes, urine protein, microalbuminuria, and blood gas analysis. PRC and PAC were measured at Fuwai Hospital by means of a chemiluminescence immunoassay using the LIAISON Direct Renin kit (DiaSorin S.p.A, Vercelli, Italy) and the LIAISON Aldosterone kit (DiaSorin Inc., Stillwater).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.