The largest database of trusted experimental protocols

5 protocols using mito sox probe

1

Oxidative Stress Evaluation in Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
DMEM-F12 medium, phosphate buffered solution (PBS) fetal bovine serum (FBS), DCFH-DA probe and mitochondria-targeted MitoSOX probe (M36008) were purchased from Invitrogen. Hcy, ATX, MTT, propidium iodide (PI) were obtained from Sigma. TUNEL-DAPI kit, Mito-SOX probe and BCA assay kit were purchased from Beyotime Institute of Biotechnology (Shanghai, China). Primary antibodies, including cleaved PARP (#94885), active-caspase-3 (#9664), active-caspase-7 (#8438), active-caspase-9 (#9507), Bax (#2772), Bad (#9292), Bcl-xL (#2764), Ser428-ATR (#2853), Ser15-p53 (#9284), total-p53 (#2524), and Ser139-histone (#9718) were all obtained from Cell Signaling Technology (Beverly, USA). Bcl-2 (#14-6992-82), CD-34 (#MA1-10202) and Ser-1981-ATM (#14-9046-82) were bought from Invitrogen (Carlsbad, USA). All solvents used were of high performance liquid chromatography (HPLC) grade.
+ Open protocol
+ Expand
2

Oxidative Stress Evaluation Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
DMEM-F12 medium, phosphate buffered solution (PBS), foetal bovine serum (FBS), and DCFH-DA probe were all purchased from Invitrogen. MTT, propidium iodide (PI) and other agents were obtained from Sigma. TUNEL-DAPI kit, Mito-SOX probe and BCA assay kit were purchased from Beyotime Institute of Biotechnology (Shanghai, China). All primary antibodies were obtained from Cell Signalling Technology (Beverly, USA). All solvents used were of high-performance liquid chromatography (HPLC) grade.
+ Open protocol
+ Expand
3

Mitochondrial ROS Detection Using mitoSOX

Check if the same lab product or an alternative is used in the 5 most similar protocols
The mitoSOX probe (Beyotime Institute of Biotechnology) was used to determine mtROS production. First, cells were seeded onto 6-well cell culture plates. After 24 h of incubation, G-Rh2 specificity was determined by pretreating HeLa cells with mitoQ (5 µM) for 1 h prior to treatment with G-Rh2 (35 and 45 µM) for 24 h. The cells were collected by centrifugation and washed with cold PBS prior to adding 5 µM mitoSOX probe (cat. no. M36008; Invitrogen; Thermo Fisher Scientific, Inc.) and incubating the mixture at 37°C for 20 min in the dark. The cells were then washed twice with PBS, 200 µl cell suspension (1×106 cells/ml) was added to the 96-well black plate and fluorescence units were detected with an Infinite M200 PRO plate reader (Tecan Group, Ltd.) at 510/580 nm excitation/emission wavelengths.
+ Open protocol
+ Expand
4

Comprehensive Cell Viability Assays

Check if the same lab product or an alternative is used in the 5 most similar protocols
TUNEL-DAPI kit, JC-1 pobe, DCFH-DA probe, Mito-SOX probe, PI staining solution and MTT were bought from Beyotime company (Shanghai, China). DMEM medium, fetal bovine serum (FBS), and penicillin–streptomycin were purchased from Invitrogen (Carlsbad, CA, United States). All antibodies and inhibitors used in the present study were purchased from Cell Signaling Technology (Beverly, MA, United States). Water used in this study was supplemented by Milli-Q system from Millipore.
+ Open protocol
+ Expand
5

Oxidative Stress and Cell Viability Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
NB was obtained from BenFu Technology Co., Ltd. (Guangzhou, China) DMEM, PBS, FBS, 2′.7′-dichlorofluorescin diacetate (DCFH-DA) probe and mitochondria-targeted MitoSOX probe (M36008) were all purchased from Thermo Fisher Scientific (Waltham, MA, USA). Temozolomide (TMZ), MTT and propidium iodide (PI) were obtained from Sigma-Aldrich Co. (St Louis, MO, USA). TUNEL-DAPI kit, MitoSOX probe and BCA assay kit were purchased from Beyotime Institute of Biotechnology (Shanghai, China). All antibodies used in this study were obtained from Cell Signaling Technology (Beverly, MA, USA). All solvents used were of high performance liquid chromatography (HPLC) grade.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!