The largest database of trusted experimental protocols

Ultrascan 1000 2k 2k ccd

Manufactured by Ametek

The UltraScan 1000 is a 2k × 2k CCD (Charged Coupled Device) for laboratory equipment. It is designed to capture high-resolution images for scientific and research applications.

Automatically generated - may contain errors

2 protocols using ultrascan 1000 2k 2k ccd

1

Nanocomplex Surface Morphology Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Surface morphology of the prepared nanoplexes was assessed using TEM. A drop (10 μl) of aqueous solution of the nanoplexes (N/P 20) was added for 30 sec on a carbon coated, glow discharged 400-mesh TEM copper grid that was pre-coated with a Formvar®. Whatman® filter paper was then used to remove any excess liquid and the grid was air dried. Negative staining was then performed by adding a drop of freshly prepared 1% w/v phosphotungstic acid solution for 30 sec followed by removing the excess stain as described before. TEM images were captured using JEOL JEM-1230 transmission electron microscope equipped with a Gatan UltraScan 1000 2k × 2k CCD acquisition system. Captured images were processed using ImageJ (Image Processing and Analysis in Java, Version 1.47).
+ Open protocol
+ Expand
2

Transmission Electron Microscopy of Plant Leaves

Check if the same lab product or an alternative is used in the 5 most similar protocols
Transmission electron microscopy was conducted as described previously in Caplan et al. (2015) (link). Leaf excisions were fixed with 2% paraformaldehyde and 2% gluaraldehyde in PHEM (60 mM PIPES, 25 mM HEPES, 10 mM EGTA, and 2 mM MgCl2, pH 6.9) buffer for 45 min) overnight at 4°C. Samples were washed with 0.1 M sodium cacodylate buffer (pH 7.4), postfixed with 1% osmium tetroxide in the same buffer for 2 hr, and then washed with buffer and water. Samples were dehydrated in an acetone series (25%, 50%, 75%, 95%, and twice in anhydrous 100% acetone; 30 min each step) and infiltrated with Quetol 651-NSA resin. Ultrathin serial sections were cut on a Reichert-Jung Ultracut E ultramicrotome and collected onto a film of 0.5% formvar using 2 × 1 single slot grids. Sections were post-stained with methanolic uranyl acetate and Reynolds’ lead citrate and examined with a Zeiss Libra 120 TEM operating at 120kV. Images were acquired with a Gatan Ultrascan 1000 2k × 2 k CCD.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!