The largest database of trusted experimental protocols

2 protocols using human il 8 flex set

1

Quantification of MMP1 and CXCL8 in MSCs

Check if the same lab product or an alternative is used in the 5 most similar protocols
MMP1 was quantified by the human MMP1 enzyme-linked immunosorbent assay (ELISA) kit (Abcam, Cambridge, United Kingdom) according to manufacturer’s instructions in undiluted samples. Absorbance was analyzed by a Mithras LB 940 microplate reader (Berthold Technologies). CXCL8 was quantified by cytometric bead array (CBA) using the human IL-8 flex-set and BD CBA human soluble protein master buffer kit (BD Biosciences) following the manufacturer’s protocol. Here, cell culture supernatants were applied in 1:50 dilution to range within the standard curve. Data was acquired on a FACS Canto II flow cytometer and analyzed with FCAP software (BD Biosciences). Protein concentrations produced by 2.5 × 105 MSCs/ml were calculated.
+ Open protocol
+ Expand
2

Cytokine Profile Analysis in Serum and Lung

Check if the same lab product or an alternative is used in the 5 most similar protocols
For human samples, venous blood was collected and the serum was separated by centrifugation at 700 × g and stored at −80°C until analyzed. The cytokines in human serum were analyzed by CBA. Briefly, IL-1β, IL-6, IL-8, MIP-1β, TNF-α, and MCP-1 concentrations of CB workers and control workers were measured. Human Soluble Protein Master Buffer Kit, Human IL-1β Flex Set (Bead B4), Human IL-6 Flex Set (Bead A7), Human IL-8 Flex Set (Bead A9), Human MCP-1 Flex Set (Bead D8), Human MIP-1β Flex Set (Bead E4), and Human TNF Flex Set (Bead C4) were used according to the manufacturer’s protocol (BD Biosciences). Data were acquired on BD Canto and BD LSRFortessa flow cytometers and analyzed by FCAP Array Software (Soft Flow Inc., Pecs, Hungary).
For animal samples, the blood was collected from angular vein after deep anesthetization with chloral hydrate. The angular vein is a small vein near the eye. The angular vein was pierced by a needle and the blood was collected. Blood and lung homogenate were centrifuged at 700 × g and then the supernatants were collected and stored at −80°C until analyzed. IL-6, IL-8, IL-1β, MIP-1β, and TNF-α were evaluated with commercially available mouse ELISA kit according to manufacturers’ recommendations (IL-6, IL-1β, MIP-1β, and TNF-α kits were from R&D Systems, Minneapolis MN and IL-8 kit was from Cusabio Biotech Company, Wuhan, China).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!