The largest database of trusted experimental protocols

1100 series analytical hplc

Manufactured by Agilent Technologies

The 1100 Series analytical HPLC is a high-performance liquid chromatography system designed for analytical applications. It provides precise separation and detection of chemical compounds.

Automatically generated - may contain errors

2 protocols using 1100 series analytical hplc

1

Chemical Modifications of PtPFPP Scaffold

Check if the same lab product or an alternative is used in the 5 most similar protocols
Chemical
modifications of the PtPFPP scaffold were performed according to the
modified methods.21 (link),22 (link) Briefly, the corresponding thiol-containing
reagent was incubated with PtPFPP in DMF/methanol at molar ratios
of 2:1–10:1 in the presence of 10 M excess of the TEA base.
Reactions were monitored on an 1100 Series analytical HPLC (Agilent)
on a YMC-Actus Triart C18, 150 × 4.5 mm2 I.D RP column,
using a 30 min gradient 0 → 100% of acetonitrile in aqueous
1% TFA and a flow rate of 0.63 mL/min. Preparative RP-HPLC purification
was performed on a Gilson PLC2250, using a YMC-Actus Triart C18, 150
× 20 mm2 I.D. RP column (YMC) and the same solvent
mixture in a 40 min gradient and a flow rate of 18.9 mL/min.
+ Open protocol
+ Expand
2

Synthetic Reagent Purification and Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols

Example 1

Materials and Methods

General

Synthetic reagents were purchased from Sigma-Aldrich, Acros, AK Scientific, or other commercial sources and were used without purification. Anhydrous solvents were obtained from commercial sources in sealed bottles. Compounds 7, 13, 21, 28, 74, and 152, as well as HIPS linkers 10, 18, and 36 were obtained commercially from Shanghai Medicilon and used without purification. Compounds 156, 157, 169, and 171 were purchased from other commercial sources; synthesis of compounds 87 and 93 was previously reported. In all cases, solvent was removed under reduced pressure with a Buchi Rotovapor R-114 equipped with a Buchi V-700 vacuum pump. Column chromatography was performed with a Biotage Isolera chromatography system. Preparative HPLC purifications were performed using a Waters preparative HPLC unit equipped with a Phenomenex Kinetex 5 μm EVO C18 150×21.2 mm column. HPLC analyses were conducted on an Agilent 1100 Series Analytical HPLC equipped with a Model G1322A Degasser, Model G1311A Quarternary Pump, Model G1329A Autosampler, Model G1314 Variable Wavelength Detector, Agilent Poroshell 120 SB C18, 4.6 mm×50 mm column at room temperature using a 10-100% gradient of water and acetonitrile containing 0.1% formic acid. HPLCs were monitored at 254 or 205 nm.

+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!