The largest database of trusted experimental protocols

Zetaplus system

Manufactured by Brookhaven Instruments

The ZetaPlus system is a versatile instrument designed for the measurement of zeta potential and particle size distribution. It utilizes electrophoretic light scattering technology to determine the surface charge characteristics and size of particles suspended in a liquid medium.

Automatically generated - may contain errors

2 protocols using zetaplus system

1

Evaluating Nano-ORL Formulations

Check if the same lab product or an alternative is used in the 5 most similar protocols
5 wt %, 10 wt %, and 20 wt % Nano-ORL formulations were synthesized in order to test the effect of ORL loading on NP size and zeta-potential. 0 wt % (empty NPs), 5 wt %, 10 wt %, and 20 wt % ORL formulations were dissolved in pure H2O to a concentration of 1.0 mg/mL. Hydrodynamic diameter was then determined using a ZetaPlus system with onboard dynamic light scattering (DLS) analyzer (Brookhaven Instruments Corporation; Holtsville, NY). Zeta potential was determined using a Zetasizer Nano ZS90 (Malvern Instruments; Worcestershire, U.K.).
+ Open protocol
+ Expand
2

Characterization of ICG-Loaded Nanoparticles

Check if the same lab product or an alternative is used in the 5 most similar protocols
NanoICG or empty NPs (empty NPs underwent the same dialysis treatment, but without ICG) were diluted to a concentration of 0.1 mg/mL in PBS and filtered through a 0.45 um filter (Fisher Scientific; Pittsburgh,PA). The hydrodynamic diameter (HD) of the NP-containing solutions was determined on ZetaPlus system with an onboard dynamic light scattering (DLS) analyzer (Brookhaven Instruments Corporation; Holtsville, NY). Absorbance (extinction) spectra were obtained on a UV-2600 (Shimadzu Scientific Instruments; Columbia MD). Fluorescence spectra were obtained on a FluoroMax-4 fluorescence spectrometer equipped with a NIR extended range PMT (Horiba Jobin Yvon; Edison, NJ). Spectra were obtained on aqueous solutions containing NPs and disassembled NP contents by addition of an equal volume of DMSO. ICG-loading content was determined with absorbance spectroscopy with a standard curve of ICG in 1:1 H2O/DMSO.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!