The largest database of trusted experimental protocols

2 protocols using bovine serum albumin fraction 5

1

UHPLC-DAD-ESI-MS Analysis of Bioactive Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents used for UHPLC-DAD-ESI-MS, i.e., acetonitrile (99.9%, LC/MS grade) and water (LC/MS grade), were purchased from Thermo Fisher Scientific (Waltham, MA, USA). Petroleum ether (95% GC/MS grade, 40–65 °C) and n-alkanes (C8–C20) were purchased from Carlo Erba Reagents S.A.S. (Barcelona, Spain) and Fluka, Sigma-Aldrich (Burlington, MA, USA), respectively. Methanol (99.8%, HPLC grade) and water (HPLC grade) used for the extraction were purchased from Thermo Fisher Scientific (Waltham, MA, USA). HPLC reference standards rosmarinic (≥99% analytical standard) and carnosic acid (≥90%) were purchased from Extrasynthese (Genay Cedex, France), while luteolin 7-O-glucoside (≥95%) was from Phytolab (Vestenbergsgreuth, Germany). Bovine Serum Albumin (BSA) Fraction V (lyophilized powder >95%) was purchased from Pan Biotech (Aidenbach, Germany), 2-deoxy-d-ribose (>99%) from Alfa Aesar (Kandel, Germany), aminoguanidine bicarbonate salt (>98%) from Sigma-Aldrich (St. Louis, MO, USA), sodium azide (>99%) and trichloroacetic acid (TCA) (>99.5%, pharma grade) from PanReac AppliChem ITW Reagents (Barcelona, Spain). Anhydrous sodium sulphate (>99%) was purchased from Penta Chemicals (Prague, Czech Republic) while disodium hydrogen phosphate (>99%) and sodium dihydrogen phosphate dihydrate (>99%) were purchased from Merck (Kenilworth, NJ, USA).
+ Open protocol
+ Expand
2

PET Polymer Characterization Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Polyethylene terephthalate (PET) (CAS: 25038-59-9, Cat. no. 429252) granules, as well as deuterated chloroform (>99% grade) were obtained from Sigma Aldrich-Merck (St. Louis, MO, USA). Bovine serum albumin (BSA) fraction V was purchased from Pan-Biotech (Aidenbach, Germany), while sodium dodecyl sulfate (SDS, analytical grade) was from Serva (Heidelberg, Germany). Trifluoroacetic acid (TFA, ≥99.5%, Optima™ LC/MS grade) was obtained from Fisher Chemical (Oxford, UK). LACE6C low speed centrifuge 3672× g (COLO LAbExperts, Novo Mesto, Slovenia) and ultrasonic bath (Sonorex Super RK52, 230 V, 50/60 Hz) from Bandelin electronic GmbH & Co. KG (Berlin, Germany) were used. All sonication steps were done by continuous sonication at 35 kHz and HF peak power 60 W. 1H NMR spectra were recorded with Varian/Agilent NMR 400 MHz. deuterated chloroform (CDCl3) used for 1H NMR (>99.9%) was from Sigma Aldrich-Merck (St. Louis, MO, USA). Chemical shifts are expressed in ppm, while TMS (tetramethylsilane) was used as an internal standard. Milli-Q water (Smart2Pure 3 UV/UF, Thermo Scientific, Waltham, MA, USA) was used for all experiments.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!