Agilent 1200 sl binary pumps

Manufactured by Agilent Technologies
Sourced in United States

The Agilent 1200 SL binary pumps are high-performance liquid chromatography (HPLC) pumps designed for reliable and precise solvent delivery. They feature a binary pump configuration, allowing the simultaneous delivery of two different solvents for gradient elution. The pumps are capable of delivering mobile phases at flow rates up to 5 mL/min and operating pressures up to 600 bar, making them suitable for a wide range of HPLC applications.

Automatically generated - may contain errors

2 protocols using agilent 1200 sl binary pumps

1

HPLC-MS/MS Bioanalytical Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The instrument parameters were same as Assay 2 (see Section 2.5.2) with a few modifications as described here. The HPLC system comprised of two Agilent 1200 SL binary pumps (Agilent, Palo Alto, CA, USA) and a CTC Analytics LCPAL (CTC Analytics AG, Zwingen, Switzerland) autosampler. Analytical column pump gradient conditions were as follows: 0.0–2.50 min, isocratic 40% B; 2.50–2.60 min, linear from 40% to 90% B; 2.60–4.50 min, isocratic 90% B. The analytical column flow rate was 0.150 mL/ min except for 3.60–4.50 mins when it was increased to 0.350 mL/min. The injection volume was 50 µL.
Mass spectrometric detection was carried out using ABI SCIEX API 5000 triple quadrupole mass spectrometer with positive electrospray ionization in MRM mode (see Table 1 and Table 2 for mass spectrometric parameters).
+ Open protocol
+ Expand
2

HPLC-MS/MS Quantification of Analytes

Check if the same lab product or an alternative is used in the 5 most similar protocols
High performance liquid chromatography (HPLC) system comprised of two Agilent 1200 SL binary pumps (Agilent, Palo Alto, CA, USA) and a CTC Analytics LCPAL (CTC Analytics AG, Zwingen, Switzerland) autosampler. Chromatographic separation was achieved on a Waters Acquity BEH C18, 2.1 mmx 50 mm, 1.7 µm column using 5 mM ammonium bicarbonate as mobile phase A and acetonitrile as mobile phase B. The analytical column was maintained at 50 °C. The analytical pump gradient conditions were as follows: 0.0–0.25 min, isocratic 10% B; 0.25–4.00 min, linear from 10% to 22% B; 4.00–4.50 min, linear from 22% to 90% B; 4.50–4.70 min, linear from 90% to 95%; 4.70–7.60 min, isocratic 95% B; 7.60–7.70 min, linear from 95% to 10% B; 7.70–9.00 min, isocratic 10% B. The flow rate was 0.300 mL/ min except for 5.60–7.60 mins when it was increased to 0.450 mL/min. A CTC Analytics LCPAL autosampler was used. The autosampler temperature was 2–8 °C. The injection volume was 25 µL.
Mass spectrometric detection was carried out using an AB Sciex API 5000TM triple quadrupole mass spectrometer (AB Sciex, Framingham, MA, USA) with positive electrospray ionization in multiple reaction monitoring (MRM) mode (see Table 1 and Table 2 for mass spectrometric parameters). The data were acquired using Analyst Version 1.6.2 (AB Sciex, Framingham, MA, USA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!