The largest database of trusted experimental protocols

Spectris solaris mr injection system

Manufactured by Bayer

The Spectris Solaris MR Injection System is a laboratory equipment product designed for the injection and delivery of liquid samples. It provides consistent and controlled injection of samples for various analytical applications.

Automatically generated - may contain errors

2 protocols using spectris solaris mr injection system

1

Comprehensive Liver MRI Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients underwent MRI examinations using a 3T Magnetom Trio Tim (Siemens Medical Solutions), Intera Achieva or Ingenia (Philips Medical Systems), or Discovery MR750w (GE Medical Systems) MRI scanner [24 (link)]. Dynamic MRI studies of the liver were performed using 10 mL of intravenous gadoxetate disodium (Primovist; Bayer AG) at a rate of 1 mL/sec, followed by 20 mL of 0.9% saline chaser at the same rate (Spectris Solaris MR Injection System; Medrad). T1-weighted three-dimensional gradient-echo imaging was performed before contrast injection and in the arterial phase (18 seconds after aortic enhancement using the bolus tracking method), portal venous phase (60 seconds), delayed phase (90 seconds) transitional phase (150 seconds), and hepatobiliary phase (20 minutes after contrast agent injection).
Other MRI sequences included an axial dual-echo T1-weighted breath-hold gradient echo sequence for acquisition of in-phase and out-of-phase images, an axial respiratory-triggered turbo spin-echo T2-weighted sequence with fat saturation, an axial half-Fourier acquisition single-shot turbo spin-echo T2-weighted sequence with fat saturation, and diffusion-weighted imaging with respiratory-triggered single-shot echo planar imaging sequences with b values of 0, 50, 400, and 800 sec/mm2 or 50, 400, and 800 sec/mm2.
+ Open protocol
+ Expand
2

Dynamic Liver MRI with Gadoxetate-Disodium

Check if the same lab product or an alternative is used in the 5 most similar protocols
All patients underwent MRI exam via 3.0-T Magnetom Trio Tim (Siemens Medical Solutions, Erlangen, Germany), Intera Achieva or Ingenia (Philips Medical Systems, Best, the Netherlands), or Discovery MR750w MRI unit (GE Medical Systems, Waukesha, Wis). Dynamic liver MRI was performed using 10mL of gadoxetate-disodium (Primovist; Bayer AG, Berlin, Germany) at an injection rate of 1mL/sec, followed by 20mL of 0.9% saline chaser at the same flow rate (Spectris Solaris MR Injection System; Medrad, Warrendale, PA) [20 (link)]. T1 weighted 3D gradient-echo hepatobiliary phase (HBP) was obtained 20 minutes after contrast agent injection. Other MRI sequences included in routine dynamic liver MRI are written in the S1 Text.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!