Ab triple tof 5600 6600 mass spectrometer

Manufactured by AB Sciex

The AB Triple TOF 5600/6600 Mass Spectrometer is a high-resolution, accurate-mass (HRAM) tandem mass spectrometry system. It is designed to provide precise and sensitive quantification and identification of small molecules and proteins in complex samples.

Automatically generated - may contain errors

3 protocols using ab triple tof 5600 6600 mass spectrometer

1

Metabolomic Analysis of Mysterious Fruit

Check if the same lab product or an alternative is used in the 5 most similar protocols
SD was purchased from Jiangmen, Guangdong Province, China, and was identified as a plant of the genus mysterious fruit of the Solanaceae by a researcher from Inner Mongolia Medical University. The SD samples are stored at −80°C. Methanol, acetonitrile, and formic acid used in this part of the experiment were chromatographic pure, and the other reagents were analytically pure. AB Triple TOF 5600/6600 Mass Spectrometer (AB SCIEX), Agilent 1290 Infinity LC Ultra-High Pressure Liquid Chromatograph (Agilent), and Low Temperature High Speed Centrifuge (Eppendorf 5430R) were used. Column: Waters, ACQUITY UPLC BEH Amide 1.7 μm, 2.1 mm × 100 mm column; Waters, ACQUITY UPLC HSS T3 1.8 μm, 2.1 × 100 mm column.
+ Open protocol
+ Expand
2

Comprehensive Metabolomic Profiling by GC-MS and UPLC-MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
A global metabolomics analysis was conducted using gas chromatography-mass spectrometry (GC – MS) and ultra-performance liquid chromatography – MS (UPLC – MS). The GC – MS analysis was performed using an Agilent 7890B gas chromatograph equipped with PEGASUS HT time-of-flight mass spectrometer (LECO). UPLC – MS analysis was conducted using an Agilent 1290 Infinity UPLC and AB triple TOF 5600\/6600 mass spectrometer (AB SCIEX). Sample equivalents were mixed to prepare quality controls (QCs) for the assessment of reproducibility. Detailed sample preparations, GC – MS and UPLC – MS analyses, and QC preparation are described in the Methods section of Supplementary material. Ion peaks generated from GC – MS were annotated with LECO-Fiehn Rtx5 database, whereas those from UPLC – MS were annotated with the MetDDA database and LipDDA methods. All data were log-transformed for normalization before statistical analysis.
+ Open protocol
+ Expand
3

Comprehensive UHPLC-Q-TOF MS Metabolomics

Check if the same lab product or an alternative is used in the 5 most similar protocols
This experiment uses UHPLC-Q-TOF MS technology combined with data-dependent acquisition methods to perform full-spectrum analysis of samples. AB Triple TOF 5600/6600 mass spectrometer (AB SCIEX) and Agilent 1290 Infinity LC Ultra High-Pressure Liquid Chromatograph (Agilent) were used to obtain primary and secondary mass spectrometry data at the same time and then used XCMS to perform peak extraction and metabolite identification on the data. Waters, ACQUITY UPLC BEH Amide 1.7 μm, 2.1 mm × 100 mm column and HSS T3 1.8 μm, 2.1 mm × 100 mm column were used as the columns.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!