The largest database of trusted experimental protocols

Cd47 lightswitch promoter reporter goclones rensp

Manufactured by SwitchGear Genomics

The CD47 LightSwitch Promoter Reporter GoClones (RenSP) is a laboratory equipment product designed for gene expression analysis. The core function of this product is to provide a plasmid-based reporter system that can be used to measure the activity of the CD47 gene promoter.

Automatically generated - may contain errors

2 protocols using cd47 lightswitch promoter reporter goclones rensp

1

CD47 Promoter Reporter Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The luciferase reporter assay was performed as previously described11 (link). CD47 LightSwitch Promoter Reporter GoClones (RenSP, S710450) and Cypridina TK Control constructs (pTK-Cluc, SN0322S) were obtained from SwitchGear Genomics. 45 ng of the RenSP reporter and 5 ng of the pTK-Cluc reporter construct were transfected into mouse smooth muscle cells using Lipofectamine 3000 Transfection Reagent (Thermo Scientific, Catalogue# L3000–008) and Opti-MEM I Reduced Serum Medium (Thermo Scientific, Catalogue# 31985062). After 48 hours, media was changed to fresh medium and cells were then exposed to DMSO, 50 ng/ml TNF-α + DMSO, or 50 ng/ml TNF-α + 10 μM atorvastatin. The cell lysate and supernatant were harvested 24 hours after stimulation/treatment und dual luciferase activity was measured with the LightSwitch Luciferase Assay Kit (Active Motif, Catalogue# 32031, NC0999256) and Pierce Cypridina Luciferase Glow Assay Kit (Thermo Scientific, PI16170) using an iD3 luminometer (Molecular Devices). Relative luciferase activity (RenSP/Cypridina ratio) was quantified as the percentage change relative to the basal value obtained from control-transfected cells.
+ Open protocol
+ Expand
2

CD47 Promoter Reporter Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The luciferase reporter assay was performed as previously described11 (link). CD47 LightSwitch Promoter Reporter GoClones (RenSP, S710450) and Cypridina TK Control constructs (pTK-Cluc, SN0322S) were obtained from SwitchGear Genomics. 45 ng of the RenSP reporter and 5 ng of the pTK-Cluc reporter construct were transfected into mouse smooth muscle cells using Lipofectamine 3000 Transfection Reagent (Thermo Scientific, Catalogue# L3000–008) and Opti-MEM I Reduced Serum Medium (Thermo Scientific, Catalogue# 31985062). After 48 hours, media was changed to fresh medium and cells were then exposed to DMSO, 50 ng/ml TNF-α + DMSO, or 50 ng/ml TNF-α + 10 μM atorvastatin. The cell lysate and supernatant were harvested 24 hours after stimulation/treatment und dual luciferase activity was measured with the LightSwitch Luciferase Assay Kit (Active Motif, Catalogue# 32031, NC0999256) and Pierce Cypridina Luciferase Glow Assay Kit (Thermo Scientific, PI16170) using an iD3 luminometer (Molecular Devices). Relative luciferase activity (RenSP/Cypridina ratio) was quantified as the percentage change relative to the basal value obtained from control-transfected cells.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!