The largest database of trusted experimental protocols

Elan 9000 icp mass spectrometer

Manufactured by PerkinElmer
Sourced in United States, Canada

The ELAN 9000 ICP mass spectrometer is an analytical instrument used for the quantitative determination of trace elements in a variety of sample types. It employs inductively coupled plasma (ICP) technology coupled with mass spectrometry (MS) to provide highly sensitive and accurate multi-element analysis.

Automatically generated - may contain errors

2 protocols using elan 9000 icp mass spectrometer

1

Pd Loading Quantification on Chit@MnFe2O4

Check if the same lab product or an alternative is used in the 5 most similar protocols
The elemental composition of the Pd immobilized on the surface of Chit@MnFe2O4 was determined by inductively coupled plasma mass spectrometry (ICP-MS) using a Perkin Elmer ELAN 9000 ICP mass spectrometer (USA). The loading of Pd immobilized on the surface of Chit@MnFe2O4 was determined by dissolving 1.0 mg of Pd-Chit@MnFe2O4 in 3 mL aqua regia. The solution was then topped-up with water to a total volume of 25 mL. The amount of Pd in the solution was determined by ICP-MS.
+ Open protocol
+ Expand
2

Silver Quantification in Biofilms

Check if the same lab product or an alternative is used in the 5 most similar protocols
Silver species accumulation and release was measured with inductively coupled plasma mass spectrometry (ICP-MS) using the ELAN 9000 ICP mass spectrometer (PerKinElmer, Canada). Samples were analyzed directly to measure dissolved Ag + ions and digested to measure total silver. Microwave digestion was performed as described by Wu et al. [48] (link) and briefly summarized here. 10 mL concentrated nitric acid and 2 mL ultra-pure water were added to 1 g biofilm (wet weight) or 1 mL suspension and kept at room temperature overnight for pre-digestion.
Microwave digestion was then carried out using ETHOS EZ Microwave Solvent Extraction Labstation (Milestone Inc., USA) with the following heating program: heat to 190 °C within 15 min and then hold at 190 °C for 10 min. The particle size and zeta potential of Ag-NPs was characterized using a Malvern Zetasizer Nano-ZS (Model: ZEN3600, Malvern Instruments Ltd, Worcestershire, UK). Since PVP dissolves in water completely, parameters of silver were adopted for the analysis: the refractive index was 2.0 and the absorption coefficient was 0.320 [49] .
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!