The largest database of trusted experimental protocols

Bovine heart extract

Manufactured by Avanti Polar Lipids

Bovine heart extract is a laboratory reagent derived from the heart tissue of cattle. It contains a complex mixture of lipids, proteins, and other biological molecules found naturally in the bovine heart. The extract is commonly used in various biochemical and cell culture applications as a source of essential nutrients and signaling molecules.

Automatically generated - may contain errors

2 protocols using bovine heart extract

1

Comprehensive Lipidomic Sample Preparation

Check if the same lab product or an alternative is used in the 5 most similar protocols
LCMS Optima-grade methylene chloride (DCM), methanol (MeOH), acetonitrile (ACN), and water (H2O) were purchased from Fisher Scientific; Hampton, NH, USA. LCMS-grade isopropanol (IPA) was purchased through HoneyWell (Charlotte, NC, USA). HPLC-grade ammonium acetate was acquired from Fisher Scientific. EquiSplash (Avanti Polar Lipids, Inc.; Birmingham, AL, USA), used as an internal standard, was a mixture of phosphatidylcholine-d7, PC(15:0/18:1-d7); lysophosphatidylcholine-d7, LPC(15:0/18:1-d7); phosphatidylethanolamine-d7, PE(15:0/18:1-d7); lysophosphatidylethanolamine-d7, LPE(15:0/18:1-d7); phosphatidylglycerol-d7, PG(15:0/18:1-d7); phosphatidylinositol-d7, PI(15:0/18:1-d7); phosphatidylserine-d7, PS(15:0/18:1-d7); triacylglyceride-d7, TAG(15:0/18:1-d7/15:0); diacylglyceride-d7, DAG(15:0/18:1-d7); monoacylglyceride-d7, MAG(18:1-d7); cholesterol ester-d7, CE(18:1-d7); sphingomyelin-d9, SM(d18:1/18:1-d9); and ceramide-d7 (d18:1-d7/15:0). The internal standard mix was diluted 100× with 1:1 DCM:MeOH. Bovine heart extract was purchased from Avanti Polar Lipids, Inc.
+ Open protocol
+ Expand
2

Lipid Standards for Mass Spectrometry

Check if the same lab product or an alternative is used in the 5 most similar protocols
Dichloromethane (Sigma-Aldrich), methanol and ammonium acetate (Fluka), and water (Burdick and Jackson) were LC-MS grade. Teflon coated caps and glass tubes were from VWR. 12 mm x 32 mm amber vials were from Thermo Scientific and 9 mm threaded caps were from Wheaton Inc. Internal standards (Avanti Polar Lipids, Inc.) were used for monitoring lipid class recoveries for: TAGs, D5-TAG (1,3 dipentadecanoyl-2-(9z-octadecanoyl)-sn-glycerol 2H5, Fw 810.34), GPLs, PC 17:0/14:1 (1-heptadecanoyl-2-(9z-tetradecanoyl)-sn-glycerol-phospholcholine, Fw 718.00), sphingosines, SM 18:1;2/17:0 (n-heptadecanoyl-D-erythro-sphingosylphosphocholine, Fw 717.07). Bovine heart extract (Avanti Polar Lipids, Inc.) at 0.25-2.5 ng/ml in methanol/Dichloromethane/ammonium acetate infusion solvent was used for mass (MS and MS/MS) calibration.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!