The Thrombinoscope software is a laboratory analysis tool designed to measure the generation of thrombin, a key enzyme involved in the blood coagulation process. The software provides quantitative data on the kinetics of thrombin formation and activity, supporting research and analysis in thrombosis and hemostasis.

Automatically generated - may contain errors

2 protocols using thrombinoscope software

1

Thrombin Generation Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
Frozen samples were thawed at 37 °C and thrombin generation was measured using the fluorometric CAT method31 as previously described.13 Briefly, 80 µL of PPP was added to round‐bottom 96‐well plates (Immulon 2HB, Thermofisher) containing 20 µL of calibrator or PPP reagent (Stago). Thrombin generation was initiated by the addition of 20 µL of CaCl2 and fluorogenic thrombin substrate (Z‐Gly‐Gly‐Arg‐AMC, Merck). Fluorescence was continuously measured over 60 minutes on a Fluoroskan Ascent plate reader (Thermofisher). All samples were run in triplicate with curves and results automatically generated by Thrombinoscope software (Stago). Variables derived from the thrombin generation curve include the time‐to‐curve onset (lag time), initial slope and overall ascending slope of the curve (velocity index), peak thrombin absorbance (peak), time taken to reach the peak (time to peak), area under the thrombin curve (endogenous thrombin potential [ETP]), and the time taken to reach the thrombin curve tail (time to tail) (Figure 1B). α2‐Macroglobulin levels were also calculated.
+ Open protocol
+ Expand
2

Thrombin Generation Assay in Plasma

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thrombin generation triggered by 5 pM tissue factor was measured in platelet-poor plasma using calibrated automated thrombogram (CAT) method.14 (link) The main output parameter of this assay was the area under the thrombin generation curve, which represents the endogenous thrombin potential (ETP). ETP was calculated in nM.min by the Thrombinoscope software (Stago, Valencia, Spain).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!