The largest database of trusted experimental protocols

Thiophene monomer

Manufactured by Merck Group
Sourced in India

Thiophene monomer is a heterocyclic organic compound with a five-membered aromatic ring structure containing one sulfur atom. It is a colorless liquid with a distinct odor. Thiophene monomers are commonly used as building blocks in the synthesis of various polymeric materials and organic electronic devices.

Automatically generated - may contain errors

2 protocols using thiophene monomer

1

Corrosion Resistance of Graphene-Reinforced Coatings

Check if the same lab product or an alternative is used in the 5 most similar protocols
Thiophene monomer (Merck), graphite
powder (sigma), FeCl3 (Merck), titanium(IV) isopropoxide
(TTIP) (sigma), CHCl3 (CDH), N-methyl-2-pyrrolidone
(NMP) (Merck), BADGE epoxy resins (Sigma), triethylene tetraamine
(Merck), HCl (analytical grade), NaCl (Merck), ethanol (analytical
grade), and CTAB (CDH) were used as received. The LCS specimens (substrate)
of the dimension 40.0 × 15.0 × 1.3 mm were used for salt
spray tests and morphological examinations (immersion test), whereas
circular specimens with a 1 cm2 exposed surface area were
used for electrochemical and wettability tests. The chemical composition
(wt %) of LCS is given in Table 6. Before coating, the steel specimens were ground with
different grit SiC sheets and then washed with acetone, followed by
ethanol and double-distilled water, and finally dried in hot air.
+ Open protocol
+ Expand
2

Electrochemical Sensing of Ferritin

Check if the same lab product or an alternative is used in the 5 most similar protocols
Nickel chloride hexahydrate (NiCl2·6H2O), ethanol (C2H5OH), ferric chloride (FeCl3), ferritin (10 mg/mL in 0.15 M sodium chloride from horse spleen), KOH, and glutaraldehyde (Glu) were purchased from Sigma–Aldrich, (India). Phosphate buffer saline (PBS of pH 7.0 and 5.0), cetyl trimethyl ammonium bromide (CTAB), glucose oxidase (GOx) having activity from 100,000 to 150,000 units g−1 of protein supplied by Central Drug House (CDH), (India) were used. Thiophene monomer was obtained from Merck, India. Double distilled water (DDW) was utilized throughout the investigations. The electrochemical studies were carried out in a three electrode system while using modified glassy carbon electrode (GC) as working, a Pt wire as a counter, and Ag/AgCl (3 M KCl) as a reference electrode, coupled with the potentiostat/galvanostat (PGSTAT 302 Autolab, Switzerland).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!