2 protocols using agilent eclipse c 18

1

Purification and Characterization of Phytochemicals

Check if the same lab product or an alternative is used in the 5 most similar protocols
Methanol, acetonitrile, formic acid, rutin, phloridzin and catechin were obtained from Sigma-Aldrich (Milan, Italy). Procyanidin B2, oleanolic acid, asiatic acid were obtained from Extrasynthese (Genay Cedex, France). An Agilent Eclipse XDB C-18 3.0 × 150 mm (3.5 µm) was used as stationary phase for analytical procedures. For semipreparative HPLC separation of triterpene acids, an Agilent Eclipse C-18 30 × 210 mm (5 µm) stationary phase was used. An Agilent 1100 system equipped with 1100 series diode array, Sedex 60 Evaporative Light Scattering Detector (ELSD) and Agilent 1260 series fraction collector was used for purification of triterpene acids. For LC-DAD-MS analysis an Agilent 1260 chromatograph equipped with 1260 series diode array was used (Agilent, Santa Clara, CA, USA). After the chromatography column a “T” junction split the flow to DAD and Varian MS 500 mass spectrometer (Varian, Santa Clara, CA, USA). MS spectra were acquired using two different approaches, one using Electrospray (ESI) and one Atmospheric Pressure Chemical Ionization (APCI) sources for polyphenols and triterpenes, respectively. For both analyses the spectrometer operated in negative ion mode acquiring spectra in the range m/z 50–2000.
+ Open protocol
+ Expand
2

HPLC Separation and Detection of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The analyses were carried using an Agilent Technologies HP1200 series HPLC system equipped with a quaternary gradient pump, a diode array detector, and a Chemstation data-analysis system (Agilent, Palo Alto, CA, USA). Chromatographic separation was performed at 25°C on Agilent Eclipse C18 (250 mm × 4.6 mm i.d., 5 μm particle) analytical columns (Agilent) at a flow rate of 0.8 mL/min via a ternary gradient. Eluent A consisted of 0.1% formic acid, eluent B is 0.1% formic acid in acetonitrile solution, and eluent C is 50 mmol/L ammonium acetate aqueous solution. Separation was performed with a gradient, as shown in Table 1. The injection volume was 20 μL, and the detection wavelength of the detector was set at 225 nm [28 (link)].
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!