Analytical Standards for Pesticide Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
CAP, TAP, FF, FFA, and CAP-D5 standards were obtained from Dr. Ehrenstorfer GmbH (Augsburg, Germany). FFA-D3 standard was obtained from Toronto Research Chemicals (Toronto, ON, Canada). HPLC-grade acetonitrile (ACN), methanol, ethyl acetate, and n-hexane were supplied by Merck (Darmstadt, Germany). Reagent grade ammonium hydroxide, HPLC-grade acetone, and formic acid were supplied by Sinopharm Chemical Reagent Co. (Shanghai, China). Water was purified with an Arium Pro ultrapure water purification system (Sartorius, Göttingen, Germany).
+ Open protocol
+ Expand
2

Quantitative Analysis of Veterinary Drugs

Check if the same lab product or an alternative is used in the 5 most similar protocols
Standards of CAP, TAP, FF, FFA and CAP-D5 (purity ≥99.50%) were obtained from Dr. Ehrenstorfer GmbH (Augsburg, Germany). FFA-D3 standard (purity ≥99.50%) was purchased from Toronto Research Chemicals (North York, ON, Canada). HPLC-grade solvents, including methanol, acetonitrile (ACN), ethyl acetate and n-hexane, were supplied by Merck Company (Darmstadt, Germany). HPLC-grade acetone, formic acid and guaranteed reagent grade ammonium hydroxide were provided by Sinopharm Chemical Reagent Co., Ltd. (Shanghai, China). Ultrapure water was supplied by the Sartorius-Arium pro system (Sartorius AG, Goettingen, Germany).
Individual standard stock solutions (1 mg/mL) of CAP, TAP, FF, FFA, CAP-D5 and FFA-D3 were prepared in methanol and stored at −20 °C for six months. CAP-D5 and FFA-D3 were used as internal standards. The combined standard working solution at a concentration of 10 μg/mL for each analyte was prepared by mixing equal volumes of the individual standard stock solution of CAP, TAP, FF and FFA with a concentration of 1 mg/mL and diluting with methanol. The mixed internal standard working solution at the concentration of 1.0 μg/mL was prepared by diluting the internal standard stock solutions (1 mg/mL) with methanol. The abovementioned standard working solutions were stored at −20 °C for up to three months.
+ Open protocol
+ Expand
3

Fucoxanthin and Chlorophyll A Extraction from U. pinnatifida

Check if the same lab product or an alternative is used in the 5 most similar protocols
The dried U. pinnatifida was supplied by Dalian LiaoHai Aquatic Food Trading Co., Ltd. (Dalian, China). It was stored in a sealing bag before analysis. Folin–Ciocalteu’s phenol reagent was obtained from Sangon Biotech (Shanghai) Co., Ltd. (Shanghai, China). Fucoxanthin (≥98%, HPLC grade), chlorophyll A (≥95%, HPLC grade) and gallic acid (≥98%, HPLC grade) were provided by Sigma-Aldrich Co., Ltd. (Shanghai, China). Methanol (HPLC grade) was purchased from Sibiquan Chemical Co., Ltd. (Shanghai, China). Acetone (HPLC grade) was supplied by Sinopharm Chemical Reagents Co., Ltd. (Shanghai, China). All other chemicals used for the analysis were analytical grade.
+ Open protocol
+ Expand
4

Copolymer-Based Nanoparticle Formulation

Check if the same lab product or an alternative is used in the 5 most similar protocols
SCU (>98% purity, CAS:
27740-01-8) was supplied by Laizhang Pharmaceutical Technology Co.,
Ltd. (Kunming, China). A 50:50 dl-lactide/glycolide copolymer
(PLGA, 0.2 dL/g, mol. wt. 17,000 g/mol, acid terminated) was kindly
gifted by Corbion (Gorinchem, Netherlands). Poly(ethylene glycol)
methyl ether-block-poly(lactide-co-glycolide) (PEG-PLGA, PEG average Mn 2000, PLGA average Mn 11,500), poly(vinyl
alcohol) (PVA, Mw 13,000–23,000,
87–89% hydrolyzed), and 2,3,5-triphenyltetrazolium chloride
(TTC) were purchased from Sigma-Aldrich (St. Louis, USA). Methanol
(analytical grade), acetonitrile (HPLC grade), and acetone (HPLC grade)
were purchased from Sinopharm Chemical Reagent Co., Ltd (Shanghai,
China). The hematoxylin–eosin staining kit (HE), 4′,6-diamidino-2-phenylindole
(DAPI), and dialysis bag (MWCO = 8,000–14,000 Da) were obtained
from Solarbio Life Sciences (Beijing, China). The TUNEL apoptosis
assay kit was purchased from Roche (Shanghai, China). Ultrapure water
was used throughout the experiments.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!