Cytokine Measurement in Colon and Sera

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokines in the colon and sera were measured by ELISA according to manufacturers’ instructions. IL-18 was measured using an ELISA kit (BMS618/3TEN, Affymetrix eBioscience) and all other cytokines were measured by a multiplex ELISAs (MCYTOMAG-70K, Millipore).
+ Open protocol
+ Expand
2

BAL Analysis of Airway Inflammation in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Eight days pi, mice were killed and tracheotomy was performed. The mouse lungs were flushed with 1 ml of PBS, and the retained BAL was centrifuged at 400 g for 5 min at 4 °C. The recovered supernatants were collected and stored at −80 °C until assessed for cytokine concentration, and the cell pellet were resuspended in 200 μl of 10% buffered formalin. Total cell numbers were counted using a hemocytometer. Cytokines in BAL supernatants were quantified with the Luminex xMAP system using a MILLIPLEX MAP mouse cytokine immunoassay (MCYTOMAG-70K; Millipore, Billerica, CA, USA) according to the manufacturer protocol. In brief, beads coupled with anti-CCL2, anti-IL-6, anti-interferon-γ, anti-RANTES, anti-IL-15 and anti-TNF monoclonal antibodies were sonicated, mixed and diluted 1:50 in assay buffer. For the assay, 25 μl of beads were mixed with 25 μl of PBS, 25 μl of assay buffer, and 25 μl of BAL supernatant, and incubated overnight at 4 °C. After washing, beads were incubated with biotinylated detection antibodies for 1 h and the reaction mixture was then incubated with streptavidin-phycoerythrin (PE) conjugate for 30 min at room temperature, washed and resuspended in PBS. The assay was analyzed on a Luminex 200 instrument (Luminex Corporation, Austin, TX, USA) using the Luminex xPONENT 3.1 software.
+ Open protocol
+ Expand
3

Serum Cytokine Profiling with Luminex® xMAP®

Check if the same lab product or an alternative is used in the 5 most similar protocols
Measurements of serum cytokines were by a multiplex kit MCYTOMAG-70K (Millipore, Burlington, MA) that employed Luminex® xMAP® Technology.
+ Open protocol
+ Expand
4

Metabolic Biomarker Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Plasma insulin and GLP-1 were measured with ELISA kit (STELLUX® Chemiluminescent Rodent Insulin ELISA ALPCO and EZGLP1T-36K, Millipore, respectively). Triglycerides (TGs), cholesterol, and free fatty acid (FFA) concentrations were measured by enzymatic methods (Triglycerides FS, Cholesterol FS, NEFA FS, Diasys). Cytokines were measured with a Milliplex MAP 5-Plex Kit using mouse cytokine/chemokine magnetic bead panel (MCYTOMAG-70K, Millipore), according to the manufacturer's protocol, and using a LuminexR apparatus (Bio-Plex 200, Bio-Rad).
+ Open protocol
+ Expand
5

Mouse Cytokine/Chemokine Multiplex Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
A mouse multiplex cytokine/chemokine magnetic bead panel (cat #: MCYTOMAG-70 K, Millipore, Burlington, MA) for interleukin-1α (IL-1α) and IL-1β was performed according to manufacturer directions. Samples were tested in duplicate and results were averaged.
+ Open protocol
+ Expand
6

Multiplexed Cytokine ELISA Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokine levels were determined by multiplex ELISA (MCYTOMAG-70K, Millipore) according to the manufacturer’s instructions. For the in vivo measurement of IL-1β and IL-18, the mouse IL-1β uncoated ELISA kit (88–703-88, Invitrogen) and mouse IL-18 ELISA Kit (BMS618–3TEN, Invitrogen) were used according to the manufacturer’s instructions.
+ Open protocol
+ Expand
7

Multiplex Cytokine Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
To measure the cytokine changes in the plasma samples, the levels of granulocyte colony stimulating factor (G-CSF), monocyte chemotactic protein (MCP)-1, tumor necrosis factor (TNF)-α, interferon (IFN)-γ, interleukin (IL)-1β, IL-4, IL-5, IL-6, and IL-10 were detected using a multiplex map kit (MCYTOMAG-70K, Millipore). The procedure was followed using the instructions and analyzed using Luminex 200™ (Luminex, Austin, TX, USA).
+ Open protocol
+ Expand
8

Multiplex ELISA Cytokine Profiling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Cytokine levels were determined by multiplex ELISA (MCYTOMAG-70K, Millipore) according to the manufacturer’s instructions.
+ Open protocol
+ Expand
9

Cytokine and Chemokine Quantification

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum was subject to Milliplex cytokine/chemokine assay MCYTOMAG-70K (Millipore, Sigma, Burlington, MA) for the detection and quantification of TNFα, IP-10, IL-17, IL-13, IL-10, IL-6, IL-4, IL-1α, eotaxin, IL-12, and IL-7. The assay was run at the UNC Advanced Analytics Core on DropArray™96 Plate system (Curiox Biosystems, San Carlos, CA) as recommended by the manufacturer.
+ Open protocol
+ Expand
10

Multiplex Cytokine Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
We performed a mouse multiplex mouse cytokine/chemokine magnetic bead panel for IL-1α and IL-1β, loading 25 μl of sample per well. Samples were tested in duplicates and results were averaged. We performed the ELISA according to manufacturer directions (cat #: MCYTOMAG-70 K, Millipore, Burlington, MA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!