Ec epiplan neofluar

Manufactured by Zeiss

The EC-Epiplan-NEOFLUAR is a high-performance metallurgical microscope objective lens produced by Zeiss. It is designed for reflected-light microscopy and delivers excellent optical performance for a wide range of applications. The lens features a long working distance and a high numerical aperture, providing high-resolution imaging capabilities.

Automatically generated - may contain errors

2 protocols using ec epiplan neofluar

1

Raman Spectroscopic Analysis of Stratum Corneum

Check if the same lab product or an alternative is used in the 5 most similar protocols
CRM analysis was performed using an Alpha300R Raman microscope (WiTec, Ulm, Germany) equipped with 532 nm laser source. To avoid photo damage, the power was set to 10 mW at the samples, corresponding to a laser density of 7.54 mW µm−2. A 600 lines/mm grating was selected, and the back scattered light was collected on a back illuminated deep depletion CCD detector over the spectral range 0–3600 cm−1 with a spectral resolution ~5 cm−1. Spectra were collected using a 20 × objective (Zeiss EC-Epiplan-NEOFLUAR, NA = 0.5, spot size ~1.3 µm) and the acquisition time was set to 30 s × 2 accumulations. For each disc, 20 maps were performed across the SC, to account for spatial heterogeneity. For each map, 9 spectra (3-by-3) were collected using a 4 µm step size, resulting in 180 spectra recorded per sample and a total of 1440 spectra for the study. The instrument is calibrated daily using a 2-step procedure. Firstly, the True Cal function of Project 5 (WITec, Ulm, Germany) is used. It is an automatic multipoint calibration routine performed with a mercury–argon (HgAr) light source integrated in the Raman microscope. Secondly, prior to data acquisition, a verification was done using the peak at 520.7 cm−1 from a silicon substrate.
+ Open protocol
+ Expand
2

Cardiomyocyte-Fibroblast Mechanical Coupling

Check if the same lab product or an alternative is used in the 5 most similar protocols
Matrigel (at concentration of 83μg/mL) was then coated for 12 hours on the surface of the PDMS devices. On day 1, neonatal rat ventricular cardiomyocytes (NRVMs) were seeded at 75% confluence on the devices for the mutant group, and at 90% confluence on the devices for the control group. The confluence in the 2 groups was made different in order to account for the fact that each mutant fibroblast occupies 3 times more area than each control fibroblast. On day 2, control and mutant fibroblasts were separately seeded onto their respective devices. On day 3, the cells were stained with Calcein AM (Invitrogen™), before they were imaged under dark field and fluorescence microscopy (Zeiss AxioScope A1, EC Epiplan-Neofluar, 20x, N.A.=0.5). The gold nanoparticles were also imaged under dark field microscopy. The gold nanoparticles moved when the cells were beating, due to the mechanical coupling between the cells and the substrate.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!