Morphometric analyses of arterial vessels from the entire sample were performed using video microscopy (Keyence Deutschland GmbH, Germany, Biozero BZ-8000K). The image was captured and displayed on a computer monitor using an image analysis program (Keyence Deutschland GmbH, Germany, BZ image analysis application). The perimeter of the vessel lumen was measured in every vessel and taken as the circumference (C) of a circle. Lumen-Diameter (LD) was determined from the equation LD = C/π assuming that the cross section of the vessel was circular in vivo [10 (link)]. Wall thickness (WT) was measured eight times in every vessel (i.e. every 45°) as the linear distance between endothelium and adventitia and the values were averaged. Hematoxylin positive nuclei (N) were counted in each vessel. In order to compare different vessels, the ratio of wall thickness to diameter (WT/LD) and number of nuclei to diameter (N/LD) were calculated and used for comparison between the different groups [10 (link)].
Biozero bz 8000k
The Biozero BZ-8000K is a high-performance fluorescence microscope system designed for biological and life science applications. It features a high-resolution imaging sensor, advanced optics, and intuitive software to capture and analyze fluorescent samples. The core function of the Biozero BZ-8000K is to provide users with a versatile and efficient tool for visualizing and studying fluorescent-labeled cells, tissues, and other biological specimens.
Lab products found in correlation
2 protocols using biozero bz 8000k
Morphometric Analysis of Rat Liver Vessels
Morphometric analyses of arterial vessels from the entire sample were performed using video microscopy (Keyence Deutschland GmbH, Germany, Biozero BZ-8000K). The image was captured and displayed on a computer monitor using an image analysis program (Keyence Deutschland GmbH, Germany, BZ image analysis application). The perimeter of the vessel lumen was measured in every vessel and taken as the circumference (C) of a circle. Lumen-Diameter (LD) was determined from the equation LD = C/π assuming that the cross section of the vessel was circular in vivo [10 (link)]. Wall thickness (WT) was measured eight times in every vessel (i.e. every 45°) as the linear distance between endothelium and adventitia and the values were averaged. Hematoxylin positive nuclei (N) were counted in each vessel. In order to compare different vessels, the ratio of wall thickness to diameter (WT/LD) and number of nuclei to diameter (N/LD) were calculated and used for comparison between the different groups [10 (link)].
GUS Assay for Euglena Cell Transformation
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!