The largest database of trusted experimental protocols

Iomeron 300 mg ml

Manufactured by Bracco

Iomeron 300 mg/ml is a non-ionic, water-soluble contrast medium for diagnostic imaging procedures. It contains the active ingredient iomeprol, which is an iodinated compound. Iomeron 300 mg/ml is designed to be administered intravenously or intra-arterially to enhance the visibility of internal structures during radiological examinations.

Automatically generated - may contain errors

2 protocols using iomeron 300 mg ml

1

CT Perfusion Imaging for Stroke Assessment

Check if the same lab product or an alternative is used in the 5 most similar protocols
CTP studies were performed at admission, 24 h, 7 days and 3 months post stroke. Prior to CTP scan, a NECT scan was performed to locate hypodense ischemic lesion. Each CTP scan started with an intravenous injection of 50 mL of iodinated contrast agent (Iomeron 300 mg/ml, Bracco Imaging SpA, Milan, Italy) at the rate of 4 mL/s, followed by 45 mL of saline flush at the same infusion rate. A 20-gauge catheter and cephalic vein were used in peripheral venous access for contrast injection. Each CTP acquisition used a two-phase protocol: eight 5 mm-thick slices covering a 40 mm section of the brain were scanned continuously for 45 s with images reconstructed at 0.5 s intervals and then scanned once every 15 s for another 105 s for a total acquisition time of 2.5 min. The scan parameters for both phases were 25 cm FOV, 80 kV, 100 mA, and 1 s per gantry rotation. BBB permeability-surface (BBB-PS), cerebral blood flow (CBF) and cerebral blood volume (CBV) maps were generated with the delay insensitive CT Perfusion software based on the modified Johnson-Wilson model (GE Healthcare, Waukesha, WI) [18 (link), 19 (link)].
+ Open protocol
+ Expand
2

Multimodal CT Imaging Protocol for Acute Stroke Evaluation

Check if the same lab product or an alternative is used in the 5 most similar protocols
All imaging was conducted on a 64-slice Lightspeed VCT scanner (GE Healthcare, Waukesha, WI, USA). NCCT helical scans were performed from the skull base to the vertex using the following imaging parameters: 120 kV, 340 mA, 4x5-mm collimation, 1 second/rotation, and table speed of 15 mm/rotation. CTA was performed as follows: 0.7 mL/kg contrast (maximum 90 mL), 5- to 10-second delay from injection to scanning, 120 kV, 270 mA, 1 second/rotation, 1.25-mm thick slices, and table speed 3.75 mm/rotation. CTA covered from the carotid bifurcation to vertex. CTP studies were performed at admission with a dynamic first-pass bolus-tracking methodology according to a one-phase imaging protocol consisting of an acquisition of 50-seconds continuous (cine) scans reconstructed with a 25 cm field-of-view at 0.5 second intervals to produce a series of 99 sequential images for each of eight 5 mm thick sections (792 images; matrix size = 512 × 512) which covered a total of 4 cm from the basal ganglia to the lateral ventricles. The other parameters of the cine scan were 80 kV, 100 mA and 0.5 rotation time. The cine scan was initiated 5 seconds after the automatic injection (Medrad, Indianola, PA) of 40 ml of non-ionic contrast agent (Iomeron 300 mg/ml, Bracco Imaging SpA) at the rate of 4 ml/sec into an antecubital vein.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!