The largest database of trusted experimental protocols

Optisafe

Manufactured by PerkinElmer

The OptiSafe is a lab equipment product by PerkinElmer. It is designed to provide a safe and controlled environment for sample handling and analysis.

Automatically generated - may contain errors

2 protocols using optisafe

1

Thymidine Kinase 1 Activity Assay

Check if the same lab product or an alternative is used in the 5 most similar protocols
The TK1 activity in serum samples was determined using [3H]-dThd (PerkinElmer) as the substrate essentially as described [23 (link)]. Briefly, the reaction mixture containing 10 mM Tris–HCl pH 7.6, 2 mM DTT, 5 mM MgCl2, 5 mM NaF, 5 mM ATP, 5 μM [3H]-dThd, 10 mM NH4Cl and an appropriate amount of serum in a total volume of 40 μL was incubated at 37 °C for 60 min. Aliquots of the reaction mixture were spotted onto DEAE filter paper (DEAE filtermat, PerkinElmer) and dried. The filters were then washed 2 times in 1 mM ammonium formate. Thereafter, the filters were sorted, eluted in 0.5 ml buffer (0.1 M HCl and 0.2 M KCl) and counted in a scintillation counter (Tri-carb, PerkinElmer) after the addition of scintillation fluid (OptiSafe, PerkinElmer). All samples were assayed at least 3 times, and the results are presented as the mean ± SD.
+ Open protocol
+ Expand
2

Serum TK1 Activity Measurement Protocol

Check if the same lab product or an alternative is used in the 5 most similar protocols
TK1 activity in serum samples was determined by using [3H]-dThd (PerkinElmer) as the substrate essentially as previously described [26 (link)]. The reaction mixture, containing 10 mM Tris–HCl pH 7.6, 2 mM DTT, 5 mM MgCl2, 5 mM NaF, 5 mM ATP, 5 μM [3H]-dThd, 10 mM NH4Cl and 10 μl serum without dilution in a total volume of 40 μL, was incubated at 37 °C for 60 min. Aliquots of the reaction mixture were spotted onto DEAE filter paper (DEAE filtermat, PerkinElmer) and dried. The filters were then washed 2 times in 1 mM ammonium formate. Thereafter, the filters were sorted into vials, the products were eluted with 0.5 ml buffer (0.1 M HCl and 0.2 M KCl) and counted in a scintillation counter (Tri-Carb, PerkinElmer) after the addition of scintillation fluid (Optisafe, PerkinElmer). All samples were assayed at least 3 times and the results are given as mean ± SD.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!