Oasis 96-well Plate HLB Extractions

Check if the same lab product or an alternative is used in the 5 most similar protocols
The extraction plate manifold used for Oasis 96-well plate HLB extractions was purchased from Waters Corporation (Milford, MA). The Savant DNA110 SpeedVac® used for concentrating samples was purchased from Thermo Fisher Scientific (Waltham, MA). The Agilent 7890 A GC, LTM Series II Fast GC Module, 7000 A GC-MS/MS Triple Quadrupole, 7693 Autosampler and 7697 A Headspace Sampler were purchased from Agilent Technologies. For GC-MS/MS data acquisition and processing, Agilent MassHunter workstation software included Acquisition, Qualitative and Quantitative Analysis.
+ Open protocol
+ Expand
2

Photocatalytic H2 Production from H2O

Check if the same lab product or an alternative is used in the 5 most similar protocols
The experiments were performed in 10 mL headspace vials using a 300 W Xenon arc lamp irradiated at the bottom. In a typical photocatalytic reaction, 2 mg of the sample was dispersed in 1 mL of H218O (90%, Wuhan Liutong Instrument Equipment Co., Ltd.) containing AgNO3 (2 mg) as an electron acceptor and La2O3 (2 mg) as a pH buffer agent48 (link). The airtight system was completely evacuated by using a vacuum pump. Then ~80 kPa of high-purity N2 gas was injected. The solution was first stirred for 1 h to reach absorption equilibrium and then irradiated with LED (PCX50C, Beijing Perfectlight Technology Co., Ltd, white light, 3 W). After 1 h of irradiation, the gas production was analyzed by gas chromatography-mass spectrometer (GC–MS, 7697 A Headspace Sampler, Agilent).
+ Open protocol
+ Expand
3

Ethanol Exposure Impact on Crayfish Hemolymph

Check if the same lab product or an alternative is used in the 5 most similar protocols
Hemolymph samples were collected from the pericardial sinus of adult crayfish in EDTA tubes following exposure to 0.1 and 1.0 M EtOH for 30 minutes. Samples were centrifuged for 10 minutes at 5,000 G and the supernatant was collected, frozen (-80 °C), and stored for later assessment. Ethanol concentrations were thereafter determined by GC-MS (Agilent 7820A GC coupled to a 7697A headspace sampler, Agilent Technologies, Santa Clara, CA, USA). Crayfish were euthanized immediately after hemolymph sample collections.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!