Lcms it tof spectrometer
The LCMS-IT-TOF spectrometer is a hybrid mass spectrometry instrument that combines liquid chromatography (LC) with ion trap time-of-flight (IT-TOF) mass analysis. The core function of this system is to provide high-resolution, accurate mass measurement capabilities for the identification and quantification of a wide range of chemical compounds.
Lab products found in correlation
14 protocols using lcms it tof spectrometer
Synthesis and Characterization of Novel Compounds
Detailed Analytical Techniques for Chemical Characterization
Mass Spectrometry and NMR Analysis
Characterization of 3CLpro Inhibitor
Actinide and Lanthanide Extraction Protocol
purchased from Aladdin (Shanghai Aladdin Biochemical Technology Co.
Ltd, China) and were of analytical or chromatographic grade. CH2Cl2 and THF were distilled from CaH2. The reactions were conducted under N2 unless otherwise
stated. 241Am and 152,154Eu, provided by the
China Institute of Atomic Energy, were used as radioactive tracers
in solvent extraction.
The NMR spectra were recorded on a Varian
Inova NMR spectrometer (Bruker Inc., Switzerland). Electrospray ionization
mass spectrometry (ESI-MS) data were obtained by an LCMS-IT-TOF spectrometer
(Shimadzu, Japan). The concentration of Eu was determined using an
inductively coupled plasma optical emission spectrometer (ICP-OES,
Optima8000, PerkinElmer).
The activities of 241Am
and 152,154Eu were
measured by a NaI (TI) scintillation counter. Luminescence spectroscopic
titration was obtained on a fluorescence spectrophotometer (F96pro,
China). The Transient Fluorescence spectra was measured on a Fluorolog-3
spectrofluorometer (JobinYvon, Horiba).
Enzymatic Assay for Antidiabetic Evaluation
Spectroscopic Characterization of Compounds
rotations were measured on a JASCO P2100 polarimeter (Japan). Mass
spectral data were carried out on a SHIMADZU LCMS-IT-TOF spectrometer.
The NMR experiments for all of the isolated compounds were done using
a Bruker AscendTM 400/R NMR spectrometer with the following frequencies: 1H NMR (400 MHz) and 13C NMR (100 MHz). Deuterated
methanol (CD3OD) was selected as the solvent of choice
for the NMR experiments with TMS as internal standard, and chemical
shifts were detected in δ ppm values.
Characterization and Purification Methods
Ruthenium-Catalyzed Organic Synthesis
Synthetic Characterization and Purification
About PubCompare
Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.
We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.
However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.
Ready to get started?
Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required
Revolutionizing how scientists
search and build protocols!