The largest database of trusted experimental protocols

Luna 3 m c8 2 100 column

Manufactured by Phenomenex

The Luna 3 µm C8(2) 100 Å column is a reversed-phase liquid chromatography column designed for the separation and analysis of a wide range of compounds. The column features a particle size of 3 micrometers and a pore size of 100 Angstroms, providing high efficiency and resolution for a variety of analytical applications.

Automatically generated - may contain errors

Lab products found in correlation

2 protocols using luna 3 m c8 2 100 column

1

Acrolein Exposure Quantification by LC-MS/MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
Acrolein exposure was measured as its stable metabolite, 3-hydroxylpropyl mercapturic acid (3-HPMA), using an adaptation of a published LC-MS/MS method [17 ]. Calibration curves were prepared in 250 μl urine aliquots using authentic 3-HPMA, with d6-3-HPMA as an internal standard. Samples were assayed using a Sciex 4000 MS/MS interfaced with an Agilent 1260 HPLC; separation was achieved on a Phenomenex Luna 3 µm C8(2) 100 Å column with isocratic elution [0.5% acetic acid in water (90%) and acetonitrile (10%)]. Check standard recoveries ranged from 109% to 117%, and the LOQ (limit of quantitation) for 3-HPMA was 0.275 ng/ml (ppb).
+ Open protocol
+ Expand
2

4-Chlorophenol Quantification in Urine

Check if the same lab product or an alternative is used in the 5 most similar protocols
Exposure to the phenoxyherbicide 2,4-D was measured as its soil metabolite, 4-chlorophenol (4-CP) [18 ,19 ], which is mutagenic to mammalian cells in vitro [20 ]. Urine samples were assayed for 4-CP using a previously published LC-MS/MS method [21 ]. Urine samples (1.0 ml) were spiked with d4-4-CP as an internal standard and were acid hydrolyzed to release glucuronide conjugates. The LC-MS/MS system included a Sciex 4000 MS/MS interfaced with an Agilent 1260 HPLC. Separation in the LC was achieved on a Phenomenex Luna 3 µm C8(2) 100 Å column. Check standard recoveries ranged from 71% to 120%, with an LOQ of 0.50 ng/ml (ppb).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!