The Waters Acquity UPLC-SQD mass spectrometer is a high-performance liquid chromatography (HPLC) system coupled with a single quadrupole mass spectrometer. The core function of this system is to separate, identify, and quantify chemical compounds in complex samples through the combination of liquid chromatography and mass spectrometry techniques.

Automatically generated - may contain errors

2 protocols using waters acquity uplc sqd mass spectrometer

1

Potassium Iodate-Mediated Oxidative Synthesis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents: unless otherwise indicated, all solvents and organic reagents were obtained from commercially available sources and were used without further purification. Acetone was dried by a molecular sieve. Potassium iodate (99%, Innochem) was used in this oxidative reaction.
Instrument: The reaction process was monitored by thin-layer chromatography (TLC, Yantai Jiangyou Co.Ltd, Tsingdao, Shandong, China) with silica gel plates (thickness = 0.20 mm, GF254) under UV light and LC-MS (Waters Acquity UPLC/SQD, Waters Acquity UPLC/SQD, Milford, MA, USA). Mass spectra were obtained using a Waters Acquity UPLC-SQD mass spectrometer. High-resolution mass spectra (HRMS, Thermo Scientific Exactive. Plus, 81 Wyman Street, Waltham, MA, USA) were recorded on an Agilent Technologies LC/MSD TOF spectrometer. The 1H-NMR spectra were recorded on a Varian Mercury 400 or 500 MHz instrument, and 13C-NMR spectra were recorded at 400 or 500 MHz on a Varian Mercury using dimethyl sulfoxide-d6 (DMSO-d6), methanol-d4 (CD3OD), chloroform-d (CDCl3) as the solvents and tetramethylsilane (TMS) as an internal standard.
+ Open protocol
+ Expand
2

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reaction progress was monitored using thin layer chromatography (TLC) with silica gel plates (Kieselgel 60 F254 plates, Merck) under UV light and LC-MS (Waters Acquity UPLC/ SQD). Mass spectra was obtained using a Waters Acquity UPLC-SQD mass spectrometer. 1 H NMR spectra was recorded on a Bruker Avance 300 MHz, 400 MHz or a Bruker Avance Ⅱ+ 600 MHz instrument, and 13 C NMR spectra was recorded at a Bruker 600 Avance Ⅱ+ instrument using DMSO-d 6 , MeOD-d 4 or CDCl 3 as a solvent and tetramethylsilane (TMS) as an internal standard.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!