The largest database of trusted experimental protocols

Mtp 384 target polished steel tf

Manufactured by Bruker
Sourced in Germany

The MTP 384 target polished steel TF is a laboratory equipment product manufactured by Bruker. It is a 384-well polished steel target designed for use in various analytical techniques.

Automatically generated - may contain errors

2 protocols using mtp 384 target polished steel tf

1

MALDI-TOF Mass Spectrometry of Proteins

Check if the same lab product or an alternative is used in the 5 most similar protocols
To prepare the samples for mass determination, samples which were prior desalted using C18 Zip Tips (Millipore, USA) were spotted onto a MALDI target (MTP 384 target polished steel TF, Bruker Daltonics, Bremen, Germany) along with 2 μl of α-cyano-4-hydroxycinnamic acid (α-CHCA) solution (10 mg/ml) in acetonitile/water/trifluoroacetic acid (50:50:0.1). We note that the singly charged protein species is not the dominant signal, and we believe this is due to the use of CHCA matrix. MALDI measurements were performed on an ultrafleXtreme MALDI-TOF/TOF mass spectrometer equipped with a smartbeam laser (Bruker Daltonics). FlexControl (Version 3.4) was used with the following programmed measurement parameters: laser frequency of 1,000 Hz in the positive-ion linear mode with acquisition ranging from 500 to 30,000 Da as well as in positive-ion reflector mode with acquisition ranging from 400 to 6,000 Da. Final spectra consisted of 1,000-3,000 shots per analysis.
+ Open protocol
+ Expand
2

MALDI-TOF Analysis of Protein Fibrils

Check if the same lab product or an alternative is used in the 5 most similar protocols
The samples of mature rigid fibril and worm‐like fibril were purified by MWCO 100 kDa cut‐off. The samples were analyzed by MALDI‐MS. 1 µL of the sample was spotted onto the MALDI target (MTP 384 target polished steel TF, Bruker Daltonics, Bremen, Germany) with 2 µL of α‐cyano‐4‐hydroxycinnamic acid (α‐CHCA) solution in acetonitrile/water/trifluoroacetic acid (50:50:0.1) for subsequent MALDI‐TOF measurements. The concentration of α‐CHCA was 10 mg mL−1. MALDI measurements were performed on an ultra fleXtreme MALDI‐TOF/TOF mass spectrometer equipped with a smart beam laser (Bruker Daltonics). The measurement parameters were programmed in flexControl (Version 3.4): laser frequency of 1000 Hz in the positive linear mode with acquisition ranging from 1000 to 70 000 Da. Final spectra consisted of 1000–3000 shots per analysis. The samples were also desalted using C18Zip Tips (Millipore, USA) and analyzed as above.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!