The largest database of trusted experimental protocols

Av600 nmr spectrometer

Manufactured by Bruker
Sourced in Germany, United States

The AV600 NMR spectrometer is a nuclear magnetic resonance (NMR) instrument designed for analytical and research applications. It operates at a frequency of 600 MHz and is capable of performing high-resolution NMR spectroscopy on a variety of sample types. The AV600 provides detailed structural information about chemical compounds through the analysis of their nuclear spin properties.

Automatically generated - may contain errors

35 protocols using av600 nmr spectrometer

1

NMR Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples were prepared in deuterated dimethyl sulfoxide (DMSO-d6). 1H NMR spectra (400.23 MHz) were recorded on a Bruker Avance III 400 NMR spectrometer using a 5 mm BBFO probe with z-axis gradients. 13C spectra (150.90 MHz) were recorded on a Bruker AV600 NMR spectrometer using a 5 mm TCI cryoprobe. Spectra were referenced to residual solvent and assignments were supported by both 1D and 2D experiments.
+ Open protocol
+ Expand
2

Spectroscopic Characterization of Natural Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured with a Perkin-Elmer 241 polarimeter. The UV spectra were conducted on a Shimadzu UV-2201 spectrometer. ECD spectra were recorded on a JASCO J-815 spectrometer. HRESIMS were recorded on Agilent Accurate-Mass-Q-TOF MS 6520 system equipped with electrospray ionization (ESI) source. NMR spectra were recorded on a Bruker AV-600 NMR spectrometer using TMS as an internal standard. The chromatographic silica gel (200–300 mesh) and polyamide (100–200 mesh) were purchased from Qingdao Marine Chemical Factory (Qingdao, China) and ODS (50 μm) was produced by YMC Co. LTD., Kyoto, Japan. Sephadex LH-20 was purchased from GE Healthcare. RP-HPLC separations were conducted using a Shimadzu LC-20AT liquid chromatograph with a YMC-PACK ODS-A column (250 × 10 mm, 5 μm) and Knauer K-2600 UV detector. Chiral separation was conducted in a Daicel AS-H column (250 × 4.6 mm, 5 μm) from Daicel Chemical Industries, Ltd. (Japan). TLC spots were visualized under UV light and by dipping into 10% H2SO4 in EtOH followed by heating. RAW 264.7 cells, human chronic myelogenous leukemia (K562) and human lung carcinoma (A549) cell lines were obtained from National infrastructure of cell line resource.
+ Open protocol
+ Expand
3

Enzymatic Synthesis and Purification of Glucoside

Check if the same lab product or an alternative is used in the 5 most similar protocols
Twenty-five mL of the reaction mixture (1 mg/mL GAA, 15 μg/mL BsGT110, 10 mM UDP-glucose, 10 mM MgCl2, 50 mM acetate buffer at pH 6) was carried out at 40 °C for 30 min. Afterward, an equal volume of methanol was added into the reaction mixture to stop the reaction. Fifty mL of the reaction mixture with 50% methanol was applied to a preparative YL9100 HPLC system (YoungLin, Gyeonggi-do, Korea). The stationary phase was the Inertsil ODS 3 column (10 mm, 20 i.d. × 250 mm, GL Sciences, Eindhoven, The Netherlands), and the mobile phase was the same as that in the UPLC system, but with a flow rate of 15 mL/min. The detection condition was 254 nm, and the sample volume was 10 mL for each injection. The product of each run was collected, concentrated under a vacuum, and lyophilized with a freeze dryer. From the 25 mL of reaction, 5.4 mg of the product was purified. The chemical structure of the product compound was determined with mass and NMR spectral analyses. The mass spectral analysis was performed on a Finnigan LCQ Duo mass spectrometer (ThermoQuest Corp., San Jose, CA, USA) with ESI. 1H- and 13C-NMR, HSQC, and HMBC spectra were recorded on a Bruker AV-600 NMR spectrometer (Bruker Corp., Billerica, MA, USA) at ambient temperature. Standard pulse sequences and parameters were used for the NMR experiments, and all chemical shifts were reported in parts per million (ppm, δ).
+ Open protocol
+ Expand
4

NMR Characterization of Deuterated Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All analytes were prepared in deuterated dimethyl sulfoxide (DMSO-d6) at a concentration of 20 mg/mL. 1H (600 MHz) and 13C (150 MHz) spectra were recorded on a Bruker AV600 NMR spectrometer using a 5 mm TCI cryoprobe. 1H NMR spectra were referenced to an external TMS reference at δ = 0 ppm.
+ Open protocol
+ Expand
5

NMR Characterization of DMSO-d6 Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
All analytes were prepared in deuterated dimethyl sulfoxide (DMSO-d6) at a concentration of 20mg/mL. 1H (600MHz) and 13C (150 MHz) spectra were recorded on a Bruker AV600 NMR spectrometer using a 5 mm TCI cryoprobe. 1H NMR spectra were referenced to an external TMS reference at δ = 0 ppm.
+ Open protocol
+ Expand
6

Spectroscopic Analysis of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a JASCO P-1020 digital polarimeter (Jasco Corp., Tokyo, Japan). UV spectra were recorded on a Thermo Scientific Multiskan GO microplate spectrophotometer (Thermo Scientific Co., Waltham, MA, USA) in MeOH. ECD spectra were recorded on a JASCO J-815 circular dichroism spectrometer (JASCO Electric Co., Ltd., Tokyo, Japan). IR spectra were determined on a Nicolet-Nexus-470 spectrometer (Thermo Electron Co., Madison, WI, USA) using KBr pellets. 1D and 2D NMR spectroscopic data (TMS as an internal standard) were acquired on Agilent DD2-500 (JEOL, Tokyo, Japan) and Bruker AV-600 NMR spectrometer (Bruker BioSpin GmbH Co., Rheinstetten, Germany). ESIMS and HRESIMS spectra were obtained from a Micromass Q-TOF spectrometer (Waters Corp., Manchester, UK), and a Thermo Scientific LTQ Orbitrap XL spectrometer (Thermo Fisher Scientific, Bremen, Germany). Semipreparative HPLC was performed on a Shimadzu LC-20 AT system using a RP-C18 (Waters, 5 μm, 10 × 250 mm) column.
+ Open protocol
+ Expand
7

NMR Spectroscopy of Compound Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Samples (20mg) were dissolved in D2O (1 ml, 99.8%) and stirred overnight at room temperature. 13C NMR spectra were obtained using a Bruker AV600 NMR spectrometer (Bruker Inc., Rheinstetten, Germany) operating at 150MHz. Spectra were recorded at 25°C with 57 000 transients. Acetone was used as an internal standard [7 ].
+ Open protocol
+ Expand
8

Characterization of Nanogel Drug Carriers

Check if the same lab product or an alternative is used in the 5 most similar protocols
Proton Nuclear Magnetic Resonance (1H NMR) spectra were detected on a Bruker AV 600 NMR spectrometer (Billerica, MA, United States) using deuterated dimethyl sulfoxide (DMSO-d6) as the solvent. Fourier-transform infrared spectroscopy (FT-IR) was performed on a Bio-Rad Win-IR instrument (Bio-Rad Laboratories Inc., Cambridge, MA, United States) by using potassium bromide method. The morphology of NGP/DOX and NGG/DOX nanogels were visualized on JEM-1011 transmission electron microscope (TEM; JEOL, Tokyo, Japan). Sizes of NGP/DOX and NGG/DOX were determined by dynamic laser scattering (DLS) measurement on a WyattQELS instrument (DAWN EOS, Wyatt Technology Corporation, Santa Barbara, CA, United States), and the scattering angle was set at 90°.
+ Open protocol
+ Expand
9

Multifaceted Characterization of Electrochemical Cells

Check if the same lab product or an alternative is used in the 5 most similar protocols
The FTIR spectra were collected from PerkinElmer Spectrum II FT-IR Spectrometer. The 1H NMR spectra were acquired on a Bruker AVANCE III HD 400 NMR spectrometer using deuterated DMSO as the field frequency lock. The 67Zn NMR spectra were acquired on a Bruker AV 600 NMR spectrometer using deuterated DMSO as the field frequency lock. The SEM images were collected from Hitachi SU4800. The ex situ SEM samples were obtained by disassembling the cell, extracting the electrode, washing by DI water for 3 times, and drying at vacuum (~25 °C) for 8 h.The DLS measurement was performed on DLS instrument (Zetasizer Nano ZS, Malvern Instruments Ltd) at 25 °C with scattering angle of 90° and laser wavelength of 632.8 nm. The ionic conductivities of the electrolytes were measured on a conductivity meter (DDS-11A, INESA) at ~25 °C.
+ Open protocol
+ Expand
10

NMR Analysis of MDMAR Standards

Check if the same lab product or an alternative is used in the 5 most similar protocols
For NMR analysis, the MDMAR standards and the vendor sample were prepared in deuterated dimethyl sulfoxide (DMSO-d6). 1H(600 MHz) and 13C NMR spectra were recorded on a Bruker AV600 NMR spectrometer using a 5 mm TCI cryoprobe. 1H NMR spectra were referenced to an external TMS reference at δ =0 ppm.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now