The largest database of trusted experimental protocols

6 protocols using co 2065 plus

1

HPLC Analysis of Cholesterol-Containing Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
HPLC was performed using a JASCO LC-2000 Plus series instrument (JASCO, Tokyo, Japan) equipped with an intelligent UV-VIS detector (UV-2075 Plus), a quaternary gradient pump (PV-2089 Plus), an intelligent column oven (CO-2065 Plus), an intelligent autosampler (AS-2057 Plus), an LC-Net II/ADC user interface, and ChromNAV data analysis software. A COSMOSIL Cholester column (4.6 × 250 mm, particle size 5 μm, Nacalai Tesque INC. Kyoto, Japan) was used for HPLC analyses at 40°C. The mobile phase was a 40:60 (v/v) mixture of 0.1% formic acid (Wako Pure Chemical Industries, Ltd., Osaka, Japan) in acetonitrile (Nacalai Tesque Inc., Kyoto, Japan) and 0.1% formic acid in water. The flow rate was 1 mL/min, the injection volume was 10.0 μL, and the detection wavelength was 343 nm. The CM peak was observed at 11.1 min.
+ Open protocol
+ Expand
2

Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
The general chemicals were purchased from Fujifilm Wako Pure Chemical, the Tokyo Chemical Industry, Kanto Chemical or Aldrich. The target DNAs and RNAs were purchased from JBioS (Japan) (Table 1). The 1H NMR spectra (400 MHz) were recorded by a Bruker 400 spectrometer. The 1H NMR spectra (600 MHz) and 13C NMR spectra (150 MHz) were recorded by a Bruker AVANCE III 600 spectrometer. The high resolution electrospray mass analysis was performed by a Bruker MicrOTOFQ II. The HPLC purification was performed by a JASCO HPLC System (PU-2089Plus, UV-2075Plus, FP-2015Plus and CO-2065Plus). A reverse-phase C18 column (COSMOSIL 5C18-AR-II, Nacalai tesque, 4.6 × 250 mm or 10 × 250 mm for ligand purification). MALDI-TOF MS measurements were performed by a Bruker Autoflex speed instrument using a 3-hydroxypicolinic acid/diammonium hydrogen citrate matrix.
+ Open protocol
+ Expand
3

Cheddar Cheese Amino Acid Profile

Check if the same lab product or an alternative is used in the 5 most similar protocols
The free amino acid constitution of commercial Cheddar cheese and the best cheese variety which resulted using PF 5.85, Conc. of pure protease 0.01% (v/v) and 0.6 month ripened at 10 °C were assessed by using a system called gradient HPLC (Jasco CO-2065 Plus) with pre-column phenylisothiocyanate (PITC) derivatisation (Rozan et al. 2000 (link)). Concentration of every amino acid was denoted as mg/g of sample.
+ Open protocol
+ Expand
4

Comprehensive Polymer Characterization and Intravital Imaging

Check if the same lab product or an alternative is used in the 5 most similar protocols
Molecular weight and molecular weight distribution were measured by high-performance liquid chromatography (HPLC; EXTREMA, JASCO, Tokyo, Japan) with an intelligent sampler (AS-2051Plusm, JASCO, Tokyo, Japan), intelligent HPLC pump (PU-2080 Plus, JASCO, Tokyo, Japan), dynamic mixer (MX-2080-32, JASCO, Tokyo, Japan), 4-Line Degasser (DG-2080-54, JASCO, Tokyo, Japan), intelligent column oven (CO-2065 Plus, JASCO, Tokyo, Japan), multiwavelength detector (MD-2015 Plus, JASCO, Tokyo, Japan), intelligent UV/VIS detector (UV-2070 Plus, JASCO, Tokyo, Japan), and an LC-NetⅡ/ADC (JASCO, Tokyo, Japan). The chemical composition of the synthesized polymers was evaluated by 1H nuclear magnetic resonance spectroscopy (JMTC-400/54/SS, JEOL, Tokyo, Japan). The radius of the molecules was evaluated by dynamic light scattering (Zetasizer Nano-ZS, Malvern Instruments, Malvern, United Kingdom) using a laser with a wavelength of 532 nm. The images of the cells were obtained by confocal laser scanning microscopy (CLSM; LSM 780, Carl Zeiss, Germany). Intravital CLSM was performed using a Nikon A1R (Nikon, Japan).
+ Open protocol
+ Expand
5

Amino Acid Profile and Volatile Compounds in Cheddar Cheese

Check if the same lab product or an alternative is used in the 5 most similar protocols
The free amino acid constitution of commercial Cheddar cheese and the best cheese variety which resulted using PF 5.85, Conc. of pure protease 0.01% (v/v) and 0.6 month ripened at 10 °C were assessed by using a system called gradient HPLC (Jasco CO-2065 Plus) with pre-column phenylisothiocyanate (PITC) derivatisation (Rozan et al. 2000) . Concentration of every amino acid was denoted as mg/g of sample.
Volatile Flavor Compounds Release in Cheese Sample preparation (SPME Procedures)
The static headspace solid-phase micro-extraction method (HS-SPME) were used to remove the volatile elements (Verzera et al. 2010) . The ideal cheese using PF 3.12, Conc. of pure protease 0.01% (v/v) and 0.6/3 months ripened at 10 °C and commercial Cheddar cheese were analysed for fragrance volatiles by the SPME-GC-MS technique.
+ Open protocol
+ Expand
6

Quantitative LC-UV Analysis of Pantoprazole

Check if the same lab product or an alternative is used in the 5 most similar protocols
LC-UV analysis was carried out on a JASCO HPLC system (JASCO PU-2089 Plus binary gradient pump, AS-4050 autosampler, MD-2010 Plus diode array detector and column oven [CO2065 plus]). The software used for the operation of the equipment and data processing was ChromNAV. UV detection was performed at 288 nm. Stock solutions of 1-mg/mL pantoprazole were prepared in MeOH and were further diluted with the same solvent. An injection volume of 10 μL was used, and three parallel measurements were performed in all cases. Other chromatographic conditions including validation processes are given in Section 3.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!