Q star elite esi lc ms ms mass spectrometer

Manufactured by Thermo Fisher Scientific

The Q-STAR Elite ESI-LC-MS/MS is a mass spectrometer designed for liquid chromatography-tandem mass spectrometry (LC-MS/MS) applications. It utilizes an electrospray ionization (ESI) source to generate ions from liquid samples, which are then analyzed by a quadrupole-time-of-flight (Q-TOF) mass analyzer.

Automatically generated - may contain errors

10 protocols using q star elite esi lc ms ms mass spectrometer

1

Synthesis and Purification of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents
were used as purchased from commercial sources without further purification.
Flash chromatography was performed using 300-mesh silica gel. All
reactions were monitored by TLC using silica-gel plates with fluorescence
F254 and UV-light visualization. 1H NMR spectra were recorded
on a Bruker AV-400 spectrometer at 400 MHz or a Bruker AV-500 spectrometer
at 500 MHz. 13C NMR spectra were recorded on a Bruker AV-500
spectrometer at 125 MHz. Coupling constants (J) are
expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported
in parts per million (ppm) relative to an internal standard (TMS).
Low- and high-resolution of ESI-MS was recorded on an Agilent 1200
HPLC-MSD mass spectrometer and an Applied Biosystems Q-STAR Elite
ESI-LC-MS/MS mass spectrometer, respectively. Purities of the final
compounds, 5a5r, were determined
to be >95% by reverse-phase high-performance liquid chromatography
(HPLC, Dionex Summit HPLC; Diamonsil C18 column, 5.0 μm, 4.6
× 250 mm, Dikma Technologies; PDA-100 photodiode-array detector;
ASI-100 autoinjector; p-680A pump). A flow rate of 1.0 mL/min was
used with a mobile phase of 90% MeOH in H2O with 0.1% modifier
(ammonia, v/v).
+ Open protocol
+ Expand
2

Characterization of Organic Compounds by NMR and MS

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H and 13C NMR spectra (Supplementary Materials) were recorded on a Bruker AV-400 spectrometer at 400 and 100 MHz, respectively, in CDCl3, CD3OD, (CD3)2SO, and C6D6 as indicated. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to the solvent. The high resolution of ESI-MS was recorded on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer, respectively. Unless otherwise noted, materials were obtained from commercial suppliers and used without further purification. Melting points were measured using an YRT-3 melting point apparatus (Shanghai Yice Apparatus & Equipment Co., Ltd., Shanghai, China) and were uncorrected.
+ Open protocol
+ Expand
3

Synthetic Protocols and Purification Techniques

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were used as purchased from commercial sources or indicated otherwise. Flash chromatography was performed using silica gel (300 mesh). All reactions were monitored by TLC, using silica gel plates with the fluorescence F254 displayed by UV light visualization. 1H NMR and 13C NMR spectra were recorded on a Bruker AV-400 spectrometer or Bruker AV-300. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to an internal control (TMS). Low resolution ESI-MS data were recorded on a Finnigan LCQ Advantage MAX mass spectrometer and high resolution ESI-MS data on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer. The purity of the compounds was determined by reverse phase high performance liquid chromatography (HPLC) analysis to be >95%. HPLC was performed on either LC-100 liquid chromatograph equipped with a tunable LC-100 UV detector (Shanghai Wufeng Inc., China) or Agilent 1200 series liquid chromatograph equipped with an Agilent 1200 Series UV detector (Agilent Technologies, USA). The columns used were Cosmosil 5C18 (Nacalai Tesque Inc., Japan) for general purification. A flow rate of 1.0 mL/min was used with mobile phase of MeOH in H2O with 0.1% modifier (ammonia or trifluoroacetate, v/v).
+ Open protocol
+ Expand
4

Characterization of Chemical Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols

1H and 13C NMR spectra were recorded on a Bruker AV-400 spectrometer at 400 and 100 MHz, respectively, in CD3Cl, CD3OD, (CD3)2SO and C6D6 as indicated. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to the solvent. High resolution ESI-MS spectra were recorded on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer. Unless otherwise noted, materials were obtained from commercial suppliers and were used without further purification. Melting points were measured using a YRT-3 melting point apparatus (Shanghai, China) and were uncorrected.
+ Open protocol
+ Expand
5

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were used directly as purchased from commercial sources. Flash chromatography was performed using silica gel (200–300 mesh). All reactions were monitored by thin-layer chromatography (TLC), using silica gel plates with fluorescence F254 and UV light visualization. 1H NMR spectra were recorded on a Bruker AV-400 spectrometer at 400 MHz. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to an internal control (TMS). Low-resolution ESI–MS was recorded on an Agilent 1200 HPLC-MSD mass spectrometer and high-resolution ESI–MS on an Applied Biosystems Q-STAR Elite ESI–LC–MS/MS mass spectrometer. HPLC instrument, Dionex Summit HPLC (column: Diamonsil C18, 5.0 μM, 4.6 × 250 mm (Dikma Technologies); detector, PDA-100 photodiode array; injector, ASI-100 autoinjector; pump, p-680A). A flow rate of 0.5 ml/min was used with a mobile phase of ACN in H2O with a 0.1% modifier (TFA, v/v).
+ Open protocol
+ Expand
6

Synthetic Organic Compound Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents and solvents were obtained from commercial suppliers and used without further purification. Flash chromatography was performed using silica gel (300–400 mesh). All reactions were monitored by TLC, silica gel plates with fluorescence F254 were used and visualized with UV light. 1H and 13C NMR spectra were recorded on a Bruker AV-400 spectrometer at 400 MHz and Bruker AV-500 spectrometer at 125 MHz, respectively (Bruker, Billerica, MA). Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to internal control (TMS). The low or high resolution of ESI-MS was recorded on an Agilent 1200 HPLC-MSD mass spectrometer (Santa Clara, CA) or Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer (Foster City, CA), respectively.
+ Open protocol
+ Expand
7

Analytical Method Development and Validation

Check if the same lab product or an alternative is used in the 5 most similar protocols
All commercially available
reagents and solvents were used without further purification. All
chemical reactions were monitored by thin-layer chromatography (TLC)
plates with visualization under UV light (254 or 365 nm). 1H NMR spectra were performed with a Bruker AV-400/600 spectrometer, 13C NMR spectra were recorded on a Bruker AV-600 spectrometer
at 150 MHz, and internal reference was either TMS or a deuterated
NMR solvent. Low-resolution mass spectra (MS) were recorded on an
Agilent 1200 HPLC-MSD mass spectrometer. High-resolution mass spectral
analysis was recorded on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS
mass spectrometer. The purity of all final compounds was confirmed
to be >95% by HPLC analysis with the Agilent 1260 system. The analytical
columns were the YMC-Triart C18 reversed-phase column, 5 μm,
4.6 mm × 250 mm, and a flow rate of 1.0 mL/min.
+ Open protocol
+ Expand
8

Purification and Characterization of Novel Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reagents and solvents were used directly as purchased from commercial sources. Flash chromatography was performed using silica gel (200–300 mesh). All reactions were monitored by thin-layer chromatography (TLC), using silica gel plates with fluorescence F254 and UV light visualization. 1H NMR and 13C NMR spectra were recorded on a Bruker AV-400 spectrometer and Bruker AV-600 spectrometer. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to an internal control (TMS). Low resolution ESI-MS were recorded on an Agilent 1200 HPLC-MSD mass spectrometer and high resolution ESI-MS on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer. HPLC instrument for purity analysis was as follows: Dionex Summit HPLC (column: AD-3, 5.0 μM, 4.6 mm × 250 mmL). A flow rate of 1.0 ml/min was used with a mobile phase of Isopropyl alcohol in Hexane.
+ Open protocol
+ Expand
9

Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reagents and solvents were purchased
from commercial sources and used directedly. Flash chromatography
was performed using 300-mesh silica gel. Reactions were monitored
by thin-layer chromatography using silica gel plates with fluorescence
F254 and UV light visualization. Low-resolution electrospray
ionization mass spectrometry (ESI-MS) was performed on an Agilent
1200 high-performance liquid chromatography (HPLC)-mass selective
detector mass spectrometer and high-resolution ESI-MS on an Applied
Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer. 1H NMR spectra were performed on a Bruker AV-400 spectrometer at 400
MHz or a Bruker AV-500 spectrometer at 500 MHz. 13C NMR
spectra were performed on a Bruker AV-500 spectrometer at 125 MHz.
Coupling constants (J) were expressed in hertz (Hz).
Chemical shifts (δ) of NMR were reported in parts per million
units relative to an internal standard (tetramethylsilane). Purity
of the compounds was determined by reverse-phase high-performance
liquid chromatography (HPLC) analysis to be >95%. HPLC instrument:
Dionex Summit HPLC (column: Diamonsil C18, 5.0 μm, 4.6 ×
250 mm2 (Dikma Technologies); detector: PDA-100 photodiode
array; injector: ASI-100 autoinjector; pump: p-680A). A flow rate
of 1.0 mL/min was used with mobile phase of MeOH in H2O
with a 0.1% modifier (ammonia, v/v).
+ Open protocol
+ Expand
10

NMR and Mass Spectrometry Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
1H and 13C NMR spectra were recorded on a Bruker AV-400 spectrometer at 400 and 100 MHz, respectively, in CDCl3, CD3OD, (CD3)2SO and C6D6 as indicated. Coupling constants (J) are expressed in hertz (Hz). Chemical shifts (δ) of NMR are reported in parts per million (ppm) units relative to the solvent. The high resolution of ESI-MS was recorded on an Applied Biosystems Q-STAR Elite ESI-LC-MS/MS mass spectrometer, respectively. Unless otherwise noted, materials were obtained from commercial suppliers and used without further purification. Anhydrous tetrahydrofuran (THF) was distilled from sodium-treated THF under nitrogen atmosphere and anhydrous dichloromethane (DCM) was distilled from calcium hydride-treated DCM under nitrogen atmosphere. Melting points were measured using an YRT-3 melting point apparatus (Shanghai, China) and were uncorrected. HPLC analysis condition: Sunfire C18 column (4.6 × 250 mm, 5 μm), elution by 90% methanol with 10% purified water (for compounds of 2, 3, 5, 8, 11a, 11b, 14a, 14b, 15a, 15b, 18a, 18b) or 80% methanol with 20% purified water (for compounds of 4, 6, 7, 9, 12a, 12b, 13a, 13b, 16a, 16b, 17a, 17b), rate = 1.0 ml/min, detection wavelength of 230 nm. The purity of all compounds by HPLC analysis is not lower than 95% (Supplementary data).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!