The largest database of trusted experimental protocols

2 protocols using anti mouse sn clone ser 4

1

Visualizing GBS Infection in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
All studies were approved by the UCSD Committee on the Use and Care of Animals and performed using accepted veterinary standards. Generation of Sn-deficient mice has previously been described [19 (link)]. GBS DK23 was labeled with 5-(and-6)-carboxyfluorescein (Invitrogen) per manufacturer’s instructions. Mice were intravenously infected with 2 × 108 CFU of labeled GBS via tail vein. Kidney, lung, and spleen were collected for CFU enumeration or frozen in OCT solution 1 h after infection. Spleen cryostat sections (5 μm) were fixed in acetone and blocked with 1 % BSA/PBST and AVIDIN/BIOTIN blocking kit (Vector Laboratories). The sections were stained with rat mAb anti-mouse Sn (clone SER-4) with Alexa Fluor 647-conjugated goat anti-rat IgG (Life Technologies) followed by second-step staining with biotinylated rat mAb anti-mouse F4/80 (clone CI:A3-1, Serotec) or B220 (clone RA3-6B2, BD Biosciences) with Alexa Fluor 555-conjugated streptavidin (Life Technologies). Images were from an Olympus FV1000 confocal microscope using FV1000 Viewer software.
+ Open protocol
+ Expand
2

Visualizing GBS Infection in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
All studies were approved by the UCSD Committee on the Use and Care of Animals and performed using accepted veterinary standards. Generation of Sn-deficient mice has previously been described [19 (link)]. GBS DK23 was labeled with 5-(and-6)-carboxyfluorescein (Invitrogen) per manufacturer's instructions. Mice were intravenously infected with 2 × 108 CFU of labeled GBS via tail vein. Kidney, lung and spleen were collected for CFU enumeration or frozen in OCT solution 1 h after infection. 5-μm spleen cryostat sections were fixed in acetone, and blocked with 1% BSA/PBST and AVIDIN/BIOTIN blocking kit (Vector Laboratories). Sections were stained with rat mAb anti-mouse Sn (clone SER-4) with Alexa Fluor 647-conjugated goat anti-rat IgG (Life Technologies) followed by second step staining with biotinylated rat mAb anti-mouse F4/80 (clone CI:A3-1, Serotec) or B220 (clone RA3-6B2, BD Biosciences) with Alexa Fluor 555-conjugated streptavidin (Life Technologies). Images were from an Olympus FV1000 confocal microscope using FV1000 Viewer software.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!