330 spectrometer

Manufactured by Thermo Fisher Scientific

The 330 spectrometer is a laboratory instrument designed for spectroscopic analysis. It is capable of measuring the absorption or emission spectra of samples across a specific range of wavelengths. The core function of this spectrometer is to provide precise and reliable spectroscopic data for various applications in scientific research and analysis.

Automatically generated - may contain errors

2 protocols using 330 spectrometer

1

Spectroscopic Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fourier-transform infrared spectroscopy (FT-IR) was recorded on a Thermo 330 spectrometer at 500–4000 cm−1 wavelengths and a resolution of 3 cm−1 over 32 scans. The ultraviolet–visible absorption spectrometry (UV–Vis) was measured with a TECHCOMP UV2600 Spectrometer (TECHCOMP, Shanghai, China) at 200–800 cm−1 wavelengths. 1H-nuclear magnetic resonance (NMR) spectra was recorded on a JNM-ECA 600 MHz-NMR using tetramethylsilane (TMS) (JEOL, Japan). Electrospray ionization mass spectroscopy (ESI-MS) data of TPB and the product were obtained by using a Bruker New ultrafleXtreme MALDI-TOF mass spectrometer at NL: 7,990,000, RT: 4.58–4.66, AV: 34, T: FTMS-p ESI and NL: 41,300, RT: 2.13–2.22, AV: 36, T: FTMS-p ESI. Fluorescent spectra was performed using a Hitachi F-7000 spectrometer at Sampling Interval: 5 nm, Scan speed: 12,000 nm min−1, EX Slit: 5 nm, EM Slit: 5 nm, PMT Voltage: 700 V, Contour interval: 10 nm, Temperature: room temperature.
+ Open protocol
+ Expand
2

Comprehensive Spectroscopic Analysis of TPB

Check if the same lab product or an alternative is used in the 5 most similar protocols
Fourier-transform infrared spectroscopy (FT-IR) was recorded on a Thermo 330 spectrometer at 500-4000 cm -1 wavelengths and a resolution of 3 cm -1 over 32 scans. The ultraviolet-visible absorption spectrometry (UV-Vis) was measured with a TECHCOMP UV2600 Spectrometer (TECHCOMP, Shanghai, China) at 200-800 cm -1 wavelengths. 1 H-nuclear magnetic resonance (NMR) spectrum was recorded on a JNM-ECA 600 MHz-NMR using tetramethylsilane (TMS) (JEOL, Japan). Electrospray ionization mass spectroscopy (ESI-MS) data of TPB and the product were obtained by using a Bruker New ultra eXtreme MALDI-TOF mass spectrometer at NL: 7,990,000, RT: 4.58-4.66, AV: 34, T: FTMS-p ESI and NL: 41,300, RT: 2.13-2.22, AV: 36, T: FTMS-p ESI. Fluorescent spectrum was performed using a Hitachi F-7000 spectrometer at Sampling Interval: 5 nm, Scan speed: 12000 nm min -1 , EX Slit: 5 nm, EM Slit: 5 nm, PMT Voltage: 700V, Contour interval: 10 nm, Temperature: room temperature.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!