Dri chem 7000i biochemistry analyzer

Manufactured by Fujifilm
Sourced in Japan

The DRI CHEM 7000i is a biochemistry analyzer manufactured by Fujifilm. It is designed for the quantitative analysis of various biochemical components in biological samples. The instrument utilizes dry chemistry technology to perform a range of tests, including the measurement of enzymes, proteins, lipids, and other analytes. The DRI CHEM 7000i is capable of delivering accurate and reliable results, but a detailed description of its intended use or performance characteristics is not available.

Automatically generated - may contain errors

4 protocols using dri chem 7000i biochemistry analyzer

1

Serum Biomarker Analysis in Blood Samples

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected every three days (d1, 4, 7, 10, 13, 16, 19, 22, 25, and 28) at 1400 h from jugular venepuncture using non-heparinized vacutainers (20 mL; Becton–Dickinson, Belliver Industrial Estate, PL6 7BP, Plymouth, UK) and ethylenediaminetetraacetic acid-treated vacutainers (4 mL; Becton–Dickinson, Franklin Lakes, NJ, USA)21 (link). Serum samples were obtained from blood after centrifugation at 2700× g at 4 °C for 15 min. Serum was transferred to a 1.5 mL tube (Eppendorf AG, Hamburg, Germany) and kept at − 80 °C until further analysis. Serum was analyzed for glucose (Fuji Dri-Chem Slide Glu-PIII, Fuji Film Corp., Tokyo, Japan) and blood urea nitrogen (BUN, Fuji Dri-Chem Slide BUN-PIIIs, Fuji Film Corp., Tokyo, Japan) using DRI CHEM 7000i biochemistry analyzer (Fuji Film, Tokyo, Japan). Non-esterified fatty acids (NEFA) was analyzed using Roche Free Fatty Acids kits (Roche, Mannheim, Germany) with HITACHI 7600 chemistry autoanalyzer (Hitachi, Tokyo, Japan). Blood cortisol was determined using a commercial Bovine ELISA test kit (Life Diagnostics, Inc, West Chester, PA, USA). Plasma was deproteinized with 10% sulfosalicylic acid for analysis of AA profiles using the AA analyzer (Sykam S433, Sykam GmbH, Germany).
+ Open protocol
+ Expand
2

Biomarker Analysis of Metabolic Hormones

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of glucose and ketone bodies were measured using a Drichem 7000i biochemistry analyzer (Fujifilm, Tokyo, Japan) and an AutoWako Total Ketone Bodies clinical assay kit (Wako, Osaka, Japan), respectively. Serum levels of adiponectin, insulin, C‐peptide 2, leptin, resistin, and gastric inhibitory polypeptide (GIP; also known as glucose‐dependent insulinotropic polypeptide 19 (link)) were measured using Multiplex Biomarker Immunoassays for Luminex xMAP technology (Millipore, Billerica, MA, USA); Catalog Nos. MADPNMAG‐70K‐01 for adiponectin; and MMHMAG‐44k for other hormones. Quantitative analyses were performed using Luminex xPONENT and MILLIPLEX Analyst 4.2 software.
+ Open protocol
+ Expand
3

Serum Biomarkers for Oxidative Stress

Check if the same lab product or an alternative is used in the 5 most similar protocols
Serum levels of alanine aminotransferase (ALT), aspartate aminotransferase (AST), and lactate dehydrogenase (LDH) were measured using a Dri-Chem 7000i biochemistry analyzer (Fujifilm, Tokyo, Japan). Serum levels of malondialdehyde (MDA) were measured using a TBARS (thiobarbituric acid-reactive substances) assay kit (Cayman Chemical, Ann Arbor, MI, USA) (Yamada et al., 2012) .
+ Open protocol
+ Expand
4

Comprehensive Blood Sampling and Analysis

Check if the same lab product or an alternative is used in the 5 most similar protocols
Blood samples were collected every three days (d1, 4, 7, 10, 13, 16, 19, 22, 25, and 28) at 1400 h from jugular venepuncture using non-heparinized vacutainers (20 mL; Becton-Dickinson, Belliver Industrial Estate, PL6 7BP, Plymouth, UK) and ethylenediaminetetraacetic acid-treated vacutainers (4 mL; Becton-Dickinson, Franklin Lakes, NJ, USA) 20 . Serum samples were obtained from blood after centrifugation at 2,700 × g at 4°C for 15 minutes.
Serum was transferred to a 1.5 mL tube (Eppendorf AG, Hamburg, Germany) and kept at -80°C until further analysis. Serum was analyzed for glucose (Fuji Dri-Chem Slide Glu-PⅢ, Fuji Film Corp., Tokyo, Japan) and blood urea nitrogen (BUN, Fuji Dri-Chem Slide BUN-PⅢ, Fuji Film Corp., Tokyo, Japan) using DRI CHEM 7000i biochemistry analyzer (Fuji Film, Tokyo, Japan). Non-esterified fatty acids (NEFA) was analyzed using Roche Free Fatty Acids kits (Roche, Mannheim, Germany) with HITACHI 7600 chemistry autoanalyzer (Hitachi, Tokyo, Japan). Blood cortisol was determined using a commercial Bovine ELISA test kit (Life Diagnostics, Inc, West Chester, PA, USA). Plasma was deproteinized with 10% sulfosalicylic acid for analysis of AA profiles using the AA analyzer (Sykam S433, Sykam GmbH, Germany).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!