The largest database of trusted experimental protocols

The BMS611 is a laboratory equipment product manufactured by Thermo Fisher Scientific. It is designed to perform specific laboratory functions. A detailed unbiased and factual description of the core function of this product is not available at this time.

Automatically generated - may contain errors

2 protocols using bms611

1

Quantification of Inflammatory Cytokines

Check if the same lab product or an alternative is used in the 5 most similar protocols
The serum levels of inflammatory markers, including IL-1β, IL-6 and TNF-α, were detected using commercial mouse TNF-α (cat. no. BMS607-3; Invitrogen; Thermo Fisher Scientific, Inc.), IL-1α (BMS611; Invitrogen; Thermo Fisher Scientific, Inc.) and IL-6 (BMS603-2, Invitrogen; Thermo Fisher Scientific, Inc.) ELISA kits. A total of 50 μl serum samples were added to the prepared microwells of the plate and diluted twice with the sample solvent. To quantify the relative protein levels, standard solutions of various concentrations were added to additional wells instead of samples. To the resulting mixtures, 50 μl diluted biotin conjugate was added and the mixture was incubated for 2 h at room temperature. Subsequently, 100 μl streptavidin-HRP was added and incubated for 1 h at room temperature. The microwells were washed multiple times and stained with tetramethylbenzidine. The intensity of staining was assessed using an EFOS-9305 spectrophotometer (Shvabe Photosystems, Moscow, Russian Federation, https://www.shvabe.com) at a wavelength of 620 nm. The concentration of substances was calculated on the basis of a calibration curve constructed from the data of a titration of standard solutions. Detection of inflammatory cytokines was performed three times.
+ Open protocol
+ Expand
2

Nasal Cytokine Profiling in Mice

Check if the same lab product or an alternative is used in the 5 most similar protocols
Mice were euthanized with 100% isoflurane following the IACUC protocol #10365. After euthanasia, the head was removed from the mouse body, and the lower mandible was discarded from the snout. Nasal wash was performed by pushing 500 μL of PBS using a plastic tube attached to a 26-gauge needle through the nasopharynx into a 1.5 mL Eppendorf tube. Nasal washes were repeated 3 times. Samples were centrifuged at 3,900 rpm for 5 min at 4 °C; the supernatant was aliquoted in 100 µL aliquots and stored at −80 °C. Concentration of IFN-I in nasal washes was determined by ELISA (42120 and 42400; PBL Assay Science) as previously described. Concentration of IFN-λ in nasal washes was determined by ELISA (DY1789B; R&D Systems) as previously described. Concentration of IFN-γ in nasal washes was determined by ELISA (KMC4021; Invitrogen) according to the manufacturer’s instructions. Concentration of IL-1α in nasal washes was determined by ELISA (BMS611; Invitrogen) according to the manufacturer’s instructions.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!