10 protocols using q tof premier spectrometer

1

Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
UV spectra were recorded on a PerkinElmer Lambda spectrophotometer. The NMR experiments were performed on a Bruker DRX-600 spectrometer at 300 K. The mass spectrometry analyses were performed with a Q-TOF premier spectrometer (Waters, Milford, MA, USA), coupled with an Alliance HPLC module (Waters, Milford, MA, USA). TLC was performed on precoated Kieselgel 60 F254 plates (Merck, Darmstadt, Germany). Column chromatography was performed over Sephadex LH-20 (Pharmacia); reversed-phase (RP) HPLC separations were conducted on a Shimadzu LC-8A series pumping system equipped with a Shimadzu RID10 A refractive index detector and a Shimadzu injector, using a Bondapak C18 column (30 cm × 7.8 mm, 10 µm, Waters, Milford, MA, USA). A Metrohm 827 pH meter, a two-channel laboratory pH measuring instrument for measuring pH/mV and temperature, was used for the pH measurement. The UE was carried out using a 320 W Ultrasonic bath (Branson 2510E-MTH, Bransonic®). The sample was placed in an Erlenmayer flask with the corresponding amount of solvent and was treated with ultrasound at 25°C for a given duration (Table 1). MAE was performed using a multimodal household microwave oven Silvercrest SMW 700 A1 at 700 W and a 100 mL flask exposed to microwave irradiation (irradiation cycle: 10 s power on, followed by 10 s power off) for a given duration (Table 1) [13 (link)–15 ].
+ Open protocol
+ Expand
2

Purification and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise specified, the reagents were purchased from commercial suppliers and used without further purification. All reactions were conducted under N2 atmosphere using undistilled solvent. Analytical thin layer chromatography (TLC) was performed using silica gel plate (0.2 mm thickness). Subsequent to elution, plates were visualized using UV radiation (254 nm). Flash chromatography was performed using Merck silica gel (200–300 mesh) for column chromatography with freshly distilled solvents. IR spectra were recorded on an FT-IR spectrophotometer using KBr optics. 1H and 13C NMR spectra were recorded in CDCl3 and DMSO-d6 on Bruker Avance or Jeol 400 MHz spectrometers. The chemical shifts (δ) are reported in ppm and coupling constants (J) in Hz. NMR splitting patterns are designated as singlet (s), doublet (d), triplet (t), quartet (q), multiplet (m), doublet of doublets (dd), doublet of triplets (dt), doublet of quartets (dq), triplet of doublets (td), triplet of triplets (tt), quartet of doublets (qd), doublet of doublet of doublets (ddd), etc. Tetramethylsilane (TMS) served as internal standard for 1H and 13C NMR analysis. High resolution mass spectra (HRMS) were obtained via a Waters Q-TOF Premier Spectrometer (ESI source).
+ Open protocol
+ Expand
3

Synthesis and Characterization of Novel Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All solvents and reagents were commercially available, and were used without further purification unless stated. The progress of the reactions was monitored by thin-layer chromatography on a glass plate coated with silica gel with a fluorescent indicator (GF254, Qingdao Ocean Chemicals, China). The melting point of target compounds were detected on the RD-1 melting apparatus (Tianjin Guoming Medical Equipment Co., LTD, China). The 1 H and 13 C nuclear magnetic resonance (NMR) spectra were recorded on a model 600 Bruker Avance spectrometer (Bruker, Germany) at 600 and 150 MHz, respectively. Chemical shifts are given in parts per million (δ) referenced to DMSO-d6 at δ 2.50 for 1 H and δ 39.5 for 13 C. High-resolution mass spectra (HRMS) of target compounds were performed by a Waters Q-TOF Premier spectrometer (Waters, USA).
+ Open protocol
+ Expand
4

Analytical Techniques for Natural Product Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
NMR spectra were recorded on Bruker AVANCE III-400 spectrometer using CDCl3 and CD3OD as solvents. Chemical shifts were reported in parts per million (ppm, δ) downfield from tetramethylsilane. HR-TOF-MS were determined by a quadruple time of flight (Q-TOF) premier spectrometer coupled with an ESI source (Waters Co., Ltd, Milford, USA). Column chromatography procedures were performed using silica gel (200–400 mesh, Qingdao Marine Chemical Ltd., China), MCI resin CHP 20P (Mitsubishi Chemistry Co. Ltd., Japan), Toyopearl gel HW-40F (TOSOH Co., Ltd., Japan), and Sephadex LH-20 (25–100 μm, Pharmacia Fine Chemical Industries Co. Ltd., Sweden). Thin-layer chromatography (TLC) was performed using silica gel GF254 precoated plates (Qingdao Marine Chemical Ltd., China). After spraying with a color reagent (10% vanillin-H2SO4 and 10% H2SO4 in EtOH), heating revealed the spots. All reagents were purchased from commercial sources without further purification.
+ Open protocol
+ Expand
5

Synthesis and Characterization of PACAP 1-38

Check if the same lab product or an alternative is used in the 5 most similar protocols
The peptide PACAP 1–38 was synthesized on a Liberty Blue peptide synthesizer (CEM Corp.) as a C-terminal amide at 0.025 mM scale using standard Fmoc synthetic methods and piperidine deprotection. The peptide was cleaved from resin and deprotected using a trifluoroacetic acid cocktail at 37°C for 30 min and precipitated using ice-cold diethyl ether. The crude peptide was purified on a Waters 1525 HPLC and Sunfire semi-prep C18 column, fitted with a 2998 photodiode array detector, using a linear gradient of water/acetonitrile, each containing 0.2% trifluoroacetic acid. Fractions containing the peptide were combined and lyophilized overnight. The fluffy white residue was analyzed by a Waters QToF Premier spectrometer in positive ion mode. Strong peaks for M +3, +4, +5 … +8 were observed, for a deconvoluted mass of 4515 Da (calculated mass 4534 Da), indicating a loss of water in the spectrometer. The HPLC trace at 220 nm absorbance indicates two peaks at 10.9 and 14.6 min which may indicate the folded and unfolded forms of the peptide.
+ Open protocol
+ Expand
6

Analytical Methods for Compound Characterization

Check if the same lab product or an alternative is used in the 5 most similar protocols
Briefly optical rotations were measured on a Perkin-Elmer 241 polarimeter equipped with a sodium lamp (589 nm) and a 1 dm microcell. UV spectra were recorded on a Perkin-Elmer-Lambda spectrophotometer. NMR experiments were performed on a Bruker DRX-600 spectrometer at 300 K. HRESIMS were acquired in positive ion mode on a Q-TOF premier spectrometer equipped with a nanoelectrospray ion source (Waters-Milford, MA, USA). Column chromatography was performed over Sephadex LH-20 (Amersham Biosciences; Uppsala, Sweden). Silica gel 60 (0.040–0.063 mm; Carlo Erba; Milan, Italy) was used as column material. HPLC separation was conducted on a Shimadzu LC-8A series pumping system equipped with a Shimadzu RID-10A refractive index detector and Shimadzu injector on a C18μ-Bondapak column (30 cm x 7.8 mm, 10 μm Waters, flow rate 2.0 mL min−1). TLC was performed on precoated Kiesel gel 60 F254 plates (Merck; Darmstadt, Germany); compounds were detected by Ce(SO4)2/H2SO4 (Sigma-Aldrich, Milan, Italy) solution; and reagent grade chemicals (Carlo Erba; Milan, Italy) were used throughout [6 (link), 7 (link)].
+ Open protocol
+ Expand
7

Structural Characterization of Natural Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotations were measured on a Rudolph Research Analytical Autopol IV polarimeter equipped with a sodium lamp (589 nm) and a 1-dm microcell. NMR experiments were performed on a Bruker DRX-600 spectrometer (Bruker BioSpin GmBH, Rheinstetten, Germany) equipped with a Bruker 5-mm TCI CryoProbe at 300 K. All 2D NMR spectra were acquired in methanol-d4 (99.95%, Sigma-Aldrich, St. Louis, MO, USA), and standard pulse sequences and phase cycling were used for DQF-COSY, HSQC, and HMBC spectra. ESI-MS were obtained using a Finnigan LC-Q Advantage Thermoquest spectrometer, equipped with Xcalibur software. HR-ESIMS spectra were acquired in positive ion mode on a Q-TOF premier spectrometer (Waters, Milford, Massachusetts, USA). TLC was performed on pre-coated Kieselgel 60 F254 plates (Merck KGaA, Darmstadt, Germany); compounds were detected by spraying with Ce(SO4)2/H2SO4 solution. Column chromatography was performed over silica gel (70–220 mesh, Merck); reversed-phase (RP) HPLC separations were conducted on a Shimadzu LC-20AT series pumping system equipped with a Shimadzu RID10A refractive index detector and a Shimadzu injector.
+ Open protocol
+ Expand
8

Synthesis and Characterization of Aryl Fluorosulfates and Formates

Check if the same lab product or an alternative is used in the 5 most similar protocols
Unless otherwise stated, all reagents were purchased from commercial suppliers and used without further purification. All the aryl fluorosulfates 1 and aryl formates 2 were prepared by following reported method [40 (link),73 (link),80 (link)]. Analytical thin layer chromatography (TLC) was performed using silica gel plate (0.2 mm thickness). Subsequent to elution, plates were visualized using UV radiation (254 nm). Flash chromatography was performed using Merck silica gel (200–300 mesh) for column chromatography with freshly distilled solvents. IR spectra were recorded on a FT-IR spectrophotometer using KBr optics. 1H, 13C, and 19F NMR spectra were recorded in CDCl3 on Bruker Avance or Jeol 400 MHz spectrometers. Tetramethylsilane (TMS) served as internal standard for 1H, 13C and 19F NMR analysis. High resolution mass spectra (HRMS) were obtained on a Waters Q-TOF Premier Spectrometer (ESI source).
+ Open protocol
+ Expand
9

Spectroscopic Characterization of Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
Optical rotation was measured using a Jasco P-1020 polarimeter (Jasco, Tokyo, Japan). Nuclear magnetic resonance (NMR) spectra were recorded on a Bruker (AM 500 MHz) FT-NMR spectrometer using tetramethylsilane as an internal standard. High-resolution electrospray ionization mass spectrometry (HRESIMS) was performed using a Waters Q-TOF Premier spectrometer. All solvents used for column chromatography were of analytical grade (SK Chemicals Co., Ltd., Seongnam-si, Korea). The solvents used for ultra-performance liquid chromatography (UPLC) were of liquid chromatography/mass spectrometry (LC/MS) grade (SK Chemicals Co., Ltd.).
+ Open protocol
+ Expand
10

Synthesis and Characterization of Organic Compounds

Check if the same lab product or an alternative is used in the 5 most similar protocols
All reactions were carried out with magnetic stirring and in dried glassware. The reactions were monitored by thin-layer chromatography (TLC: HG/T2354–92, GF254), and compounds were visualized on TLC with UV light. All chemicals and solvents were purchased from commercial sources and used without purification treatment. Analytical thin-layer chromatography was carried out on 0.20 mm silica gel plates (Haiyang, Qingdao, Shandong, China) with the QF-254 UV indicator. Column chromatography was conducted using Haiyang silica gel 60 (300–400 mesh). Melting points were determined with an X-4 apparatus and were uncorrected. The nuclear magnetic resonance (NMR) spectra were recorded on a Bruker 400 MHz spectrometer in CDCl3 or DMSO-d6 using tetramethylsilane (TMS) as an internal standard. Peak multiplicity of NMR signals were as follows: s, singlet; brs, broad singlet; d, doublet; t, triplet; q, quartet; m, multiplet. Chemical shift (δ): ppm relative to Me4Si (internal standard). Coupling constant: J (Hz). High-resolution mass spectra (HRMS) of all target compounds were performed by a Waters Q-TOF Premier spectrometer with acetonitrile and water as solvents. Electrospray ionization mass spectrometry (ESI-MS) analyses were recorded in an Agilent 1100 Series MSD Trap SL (Santa Clara, CA, USA). All final compounds are >95% pure by HPLC analysis.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!