The largest database of trusted experimental protocols

Biphenyl 100 column

Manufactured by Phenomenex

The Biphenyl 100 Å column is a high-performance liquid chromatography (HPLC) column designed for the separation and analysis of a wide range of analytes. It features a biphenyl stationary phase with a pore size of 100 Ångströms, providing efficient chromatographic separation and high-resolution performance.

Automatically generated - may contain errors

2 protocols using biphenyl 100 column

1

HPLC Analysis of Steroid Products

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reaction products were analyzed using an Agilent 1260 Infinity HPLC system with UV detector. Extracted steroid products were dissolved in 20 μL of methanol, and 5 μL injections were resolved with a 50 × 2.1 mm, 2.6 μm, biphenyl 100 Å column (Phenomenex, Torrance, CA), equipped with a guard column at a flow rate of 0.4 mL/min. A methanol/water linear gradient was used: 32.5% to 88.3% methanol from 0 to 10.6 min, 88.3% to 12 min, 99.1% from 12.1 min to 14 min, and 32.5% from 14.1 min to 15 min. Products were identified by retention times of external standards chromatographed at the beginning and ends of the experiments, and the data were processed with Laura4 software (LabLogic) and graphed with GraphPad Prism 7 (GraphPad Software, San Diego, CA).
+ Open protocol
+ Expand
2

Steroid Product Quantification by HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
Reaction products were analyzed using an Agilent 1260 Infinity HPLC system with UV detector. Extracted steroid products were dissolved in 20 μL of methanol, and 5 μL injections were resolved with a 50 × 2.1 mm, 2.6 μm, biphenyl 100 Å column (Phenomenex, Torrance, CA), equipped with a guard column at a flow rate of 0.4 mL/min. A methanol/water linear gradient was used: 32.5% to 88.3% methanol from 0 to 10.6 min, 88.3% to 12 min, 99.1% from 12.1 min to 14 min, and 32.5% from 14.1 min to 15 min. Products were identified by retention times of external standards chromatographed at the beginning and ends of the experiments, and the data were processed with Laura4 software (LabLogic) and graphed with GraphPad Prism 6 (GraphPad Software, San Diego, CA).
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!