The largest database of trusted experimental protocols

Ctan ctvol software

Manufactured by Bruker
Sourced in Belgium

The CTAn/CTVol software is a tool designed for the analysis and visualization of 3D data obtained from micro-computed tomography (micro-CT) imaging. It provides users with the ability to quantify and analyze the morphological and structural characteristics of various materials and samples.

Automatically generated - may contain errors

2 protocols using ctan ctvol software

1

Micro-CT Analysis of Femoral Trabecular Bone

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fixed femurs were scanned using high-resolution μCT (Skyscan 1272; Kontich, Belgium) with a source voltage of 60 kV, current of 166 μA, and resolution of 14 μm. Bone morphometric parameters, including bone volume per total volume (BV/TV), bone mineral density (BMD), trabecular separation (Tb. Sp.), and trabecular number (Tb. N.) were analyzed using CTAn software (Bruker; Kontich, Belgium). Micro-CT 3D images of trabecular bones in the distal femurs were generated using CTAn/CTVol software (Bruker; Kontich, Belgium).
For histology, the fixed femurs were decalcified in 12% EDTA and embedded in paraffin, and the histological tissue sections were stained with hematoxylin and eosin and TRAP.
+ Open protocol
+ Expand
2

Micro-CT Analysis of Trabecular Bone

Check if the same lab product or an alternative is used in the 5 most similar protocols
The fixed long bones were analyzed using a SkyScan 1272 high-resolution micro-CT system (Bruker, Kontich, Belgium). The scanning parameters were set at 60 kV/166 µA with a resolution of 8 µm for long bones. Three-dimensional images of the tibial trabecular bones (ROI: 0.21–1.94 mm from the growth plate) were obtained using CTAn/CTvol software (Bruker, Kontich, Belgium), and morphometric parameters including bone volume fraction (BV/TV), bone mineral density (BMD), trabecular separation (Tb. Sp.), and trabecular number (Tb. N.) were calculated using CTAn software (Bruker; Kontich, Belgium) as reported previously [31 (link),35 (link)]. For histological examination, the fixed long bones were decalcified in 10% EDTA, embedded in paraffin, and serial sections were cut to a thickness of 6 μm. The sections were stained with TRAP and used to quantify osteoclast number per bone parameter.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!