Aquasil c18 reverse phase

Manufactured by Thermo Fisher Scientific

Aquasil C18 is a reverse phase chromatography packing material. It is composed of silica particles coated with a C18 hydrocarbon chain. Aquasil C18 is used for the separation and purification of a wide range of organic compounds in liquid chromatography applications.

Automatically generated - may contain errors

2 protocols using aquasil c18 reverse phase

1

SCFA Analysis via HPLC

Check if the same lab product or an alternative is used in the 5 most similar protocols
SCFA identification and quantification was performed as in Panzella et al. (2017) (link). The equipment used was an Accela 600 HPLC (Thermo Scientific) with a quaternary pump, an autosampler and a UV-VIS PDA detector set at 210 nm. We used 0.1 M phosphate buffer (pH 2.8)/acetonitrile 99:1 v/v with a flow rate of 1.25 mL/min as mobile phase. An Aquasil C18 reverse phase (Thermo Scientific) (150 × 4.6 mm, 5 μm) was used with a run time of 30 min. The samples did not require any pretreatment before injecting except for centrifugation at 13000 rpm and further filtration through 0.22 μm nylon filter. One mL of fermentation supernatant was centrifuged and filtered prior injection of 20 μL. The SCFA standards (acetate, propionate and butyrate) were prepared in the mobile phase at concentrations ranging from 5 to 10000 ppm. Results were expressed as mM.
+ Open protocol
+ Expand
2

HPLC Analysis of Short Chain Fatty Acids

Check if the same lab product or an alternative is used in the 5 most similar protocols
Short chain fatty acids were analyzed as in Pérez-Burillo et al. 18 In vitro fermentation supernatant was filtered through a 0.22 μm nylon filter and injected into the HPLC system (Accela 600). The HPLC system was composed of a PDA detector, a multisampler and a quaternary pump. The detector was set at 210 nm; the mobile phase used was Milli-Q water with 1% of formic acid/acetonitrile with 1% of formic acid at a rate of 99 : 1 v v -1 delivered at a 1.25 mL min -1 flow rate; the column used was an Aquasil C 18 reverse phase (Thermo Scientific) (150 × 4.6 mm, 5 µm), with a total run time of 30 min. Calibration curves with standard acetate, propionate and butyrate were made at a concentration range of 10-0.01 mM. The results were expressed in mM.
+ Open protocol
+ Expand

About PubCompare

Our mission is to provide scientists with the largest repository of trustworthy protocols and intelligent analytical tools, thereby offering them extensive information to design robust protocols aimed at minimizing the risk of failures.

We believe that the most crucial aspect is to grant scientists access to a wide range of reliable sources and new useful tools that surpass human capabilities.

However, we trust in allowing scientists to determine how to construct their own protocols based on this information, as they are the experts in their field.

Ready to get started?

Sign up for free.
Registration takes 20 seconds.
Available from any computer
No download required

Sign up now

Revolutionizing how scientists
search and build protocols!